manual
HRC
70
PILOT -PREMIUM-
/2
-
-
manual
HRC
70
PILOT -PREMIUM-
/2
-
15
4.1.1 - DIsplay : Symbols and their meaning
4.1.2 - Current functioning display
4.1.3 - Unlocking
4.1.4 - Language
Heat Pump operating
(at 2
nd
power stge)
Circulators activated
(Circuit 1 circulator)
Pressure in the heating
installation
Temperature of heating
water in the Pilot, at
the outlet towards the
supplied circuit.
Current day
(Monday=1 ;
Tuesday=2....)
1 . 2 b a r
4 5
°
C
2
2
1
2
• Tuesday
• Circuit 2 requested for the
production of domestic hot water
• Heat Pump operating at 3
rd
power
stage
• Temperature of water at outlet
(primary circuit for domestic water) : 62°C
• Pressure in the installation : 1,3 bars
Example 1
1 . 3 b a r
6 2
°
C
2
2
2
2
1
1
• Thursday
• Holiday mode activated
• End of holiday mode in 14 days
Example 2
h o l i . r e t u r
1 4 d
4
• After having connected the appliance to the power supply, or in
absence of use, the control panel is automatically locked (
) after
30 minutes. When locked, the buttons are deactivated.
•
To unlock the control panel,
press «
» button for 4 seconds.
Choose the
language
Enter
L A N G U A G E
L A N G U A G E
E N
• Press
.
• Turn the dial to scroll through the menu options :
• Press
to return to the main menu.
9 character
message
Display zone for time
or temperatures
Day of the
week
Symbol
Signification
Summer mode activated
Heat Pump operating at 1
st
power stage
(compressor 1 activated, fan speed 1)
Heat Pump operating at 2
nd
power stage
(compressor 2 activated, fan speed 2)
Heat Pump operating at 3
rd
power stage
(compressor 1 and 2 activated, fan speed 3)
De-icing in progress
Electrical back-up activated
Back-up boiler activated
Heat Pump circulator activated
Heating circuit 1 circulator activated
Heating circuit 2 circulator activated
Domestic hot water production activated
Setting / Display being set
«Clock» or «Program» being set
«Comfort» mode
«Eco» mode
«Frost protection» mode
«Holiday» mode
Keyboard locked