D E A C T I V .
C
-
1
n o C T R L
A
-
1
R A D I A T o R
C
-
1
t h e r m o s t a t
a
-
1
F l o o r
C
-
1
i n t . s e n s o r
A
-
1
EXCLUSIVELY connect either:
- The AMBIENT TEMPERATURE SENSOR
with DISPLAY (Ref. 751009)
- The AMBIENT TEMPERATURE RADIO-
FREQUENCY THERMOSTAT (Ref. 751010)
All other chronoproportional type thermostats may
cause malfunctioning and render the warranty null
and void.
4.2.2.2 - Configuring circuit 1
4.2.2.3 - Circuit 1 ambient temperature control
To deactivate circuit 1
(absence of circuit or of
permanent pool
(summer
+ winter)
In the absence of an ambient
temperature control on circuit
1 (heating curve only).
For a radiator circuit installed
on circuit 1.
For a thermostat (dry contact)
controlling the ambient
temperature of circuit 1.
For an underfloor heating
circuit (low temperature)
installed on circuit 1.
For an ambient temperature
sensor with display controlling
circuit 1.
Enter
Enter
Enter
Enter
Enter
Enter
Note :
If circuit 1 is an underfloor heating circuit, an
ambient temperature control is mandatory.
n o C T R L
A
-
2
D E A C T I V .
C
-
2
t h e r m o s t a t
a
-
2
R A D I A T o R
C
-
2
f l o o r
C
-
2
w a t e r
C
-
2
(1)
Radiators are only possible on circuit 2 if
circuit 1 is also a radiator circuit (or
deactivated).
(2)
Underfloor heating is only possible on circuit 2
if circuit 1 is also an underfloor heating circuit
(or deactivated).
(3)
Domestic water circuit is only possible on circuit
2 if circuit 1 is a radiator circuit (or deactivated).
4.2.2.5 - Circuit 2 ambient temperature control
4.2.2.4 - Configuring circuit 2
In the absence of an ambient
temperature control on circuit
2 (heating curve only).
To deactivate circuit 2
(absence of a circuit)
For a thermostat (dry contact)
controlling the ambient
temperature of circuit 2.
For a radiator circuit installed
on circuit 2
(1)
For an underfloor heating
circuit (low temperature)
installed on circuit 2
(2)
For a domestic water circuit
installed on circuit 2
(3)
. To select the ambient temperature control or the domestic water
temperature control for circuit 2
Enter
Enter
Enter
Enter
Enter
Enter
Note :
If circuit 2 is an underfloor heating circuit, an
ambient temperature control is necessary.