-
manual
HRC
70
PILOT -PREMIUM-
/2
-
52
Hydraulic schematic diagram -1 DIRECT CIRCUIT and 1 MIXED CIRCUIT-
with optional 2
nd
circuit at a lower temperature (Ref.751014) -pool possible-
C PAC
= Heat Pump circuit circulator
C chauf. 1 = Heating circuit 1 circulator
CD
= Heat Pump circuit flow rate monitor
S
= Pressure relief valve set at 3 bars
P
= Air purger
SP
= HRC
70
Pilot temperature sensor (or TSeau sensor)
AQS
= 110°C safety aquastat - manual reset
CP
= Water pressure gauge
VB
= Desludging valve
VF
= Heat Pump circuit filter valve
V
= Stop valves
CA
= Check valves (to be used when the HRC
70
Pilot is installed on a higher
level than the Heat Pump so as to prevent a thermosiphon effect)
VE
= Expansion vessel
D
= Backflow prevention device
F
= Flexible hoses for connection to the Heat Pump
PM
= Manual purger
SPAC
= Heat Pump Pressure relief valve set at 2.5 bars
Te PAC
= Heat Pump water inlet sensor
Ts PAC
= Heat Pump water outlet sensor
C ch.
= Existing boiler circulator
VC
= Existing installtion expansion vessel
SCh
= Existing boiler Pressure relief valve
Sext.
= HRC
70
Pilot Heat Pump exterior sensor
TA1
or Samb1 = Heating circuit 1 ambient temperature thermostat or sensor (optional)
LTP 1
= Underfloor heating circuit 1 temperature limiter (optional)
CD
= Pool circuit flow rate monitor
SPISC
= Pool sensor (optional, included in the pool kit)
C piscine = Pool circuit circulator
VP
= 3-way valve for radiator circuit (winter) or pool circuit (summer)
CACH
= Boiler check valve
TA or SA
= «Thorix Evolution» lower temperature 2
nd
circuit ambient temperature
thermostat or sensor
On the Pilot : • The 2
nd
circuit (radiator C-2) or (floor C-2) which must be the same kind as the 1
st
circuit connected to the Pilot, MUST be
activated.
• Activate the ambient temperature thermostat (THERMOSTAT A-2) of the 2
nd
circuit in order to monitor the operation of the
Heat Pump using the on/off alert output of the Thorix Evolution (set parameter
P219 = 1
on the Thorix Evolution).