3.6.1 - Recommendations for connecting the
system to the power supply
3.6.2 - Connecting the Pilot to the power supply
Note :
See the electrical wiring diagram in the Appendix
Check :
• The input current
• Number and thickness of power supply
cables
• Fuse or circuit breaker ratings
The power supply must come from an electrical protection and
sectioning device which complies with all current rules and
regulations in effect in the country of use.
This CE-approved unit complies with all the essential requirements
of the following directives:
- Low voltage n°2006/95/CE
- Electromagnetic compatibility n° 2004/108/CE
Ensure that the installation is equipped with a properly sized and
connected grounding cable.
Ensure that the voltage and frequency of the general power
supply fits requirements.
The acceptable variation in voltage is:
230 V -10% to +6% 50Hz for single-phase + Ground models
400 V -10% to +6% 50Hz for three-phase + N Ground models
The Pilot must be protected from upstream by a combined all-
pole contact (minimum distance of separation of the contacts =
3mm : EN 60 335-1) with fuses or by a magnetic thermal circuit
breaker which is calibrated based on the power of the Pilot.
Type of back-up
Without
back-up
or back-up
boiler
Electrical current
230 V 230 V 400V
Power consumption
2 A
30 A
10 A
Calibration of the mains
switch fuses
(1)
32 A
32 A
12 A
Width of electricity supply
cable per phase
(2)
2,5 mm² min
à 4 mm² max
Number of conductors
(2)
4x2,5 mm² + T
(*)
min
à 4x4 mm² + T
(*)
max
Pilot
6 mm² min
à 10 mm² max
2x6 mm² + T
(*)
min
à 2x10 mm² + T
(*)
max
(1)
or two-pole or three-pole general circuit breaker
(2)
The sizes given are for informational purposes only. They must be verified and adapted
if nedded according to installation conditions and the current regulations in effect.
(*)
The width of the ground cable must be equal to the width of the largest cable.
6 kW electrical back-up
single-phase single-phase
three-phase
To access the terminal, dismantle the front of the Pilot and open
the electrical box by removing the two screws (rep
1
).
3 control terminals on the
electronics board:
-12-pole (HP/HC; Del;
Amb2; Amb1; Pisc; Ext)
-2-pole (sheathed cable)
-2-pole (Chaud)
Optional pool kit terminal
Primary power terminal
1
1
The HRC
70
Pilot is delivered pre-configured for
400V three-phase operation.
For 230V single-phase operation, you must
place a bridge (delivered in a bag) between the 3
phase terminals. See the diagram below :
Legend
:
PH-N
: Electrical supply Phase/Neutral 230V single-phase - 50HzCPAC
: Factory connected Heat Pump circulator
Cchauf 1 : Heating circuit 1 circulator
or Pisc
or Primary circuit pool circulator
Cchauf2 : Heating circuit 2 circulator
or ECS
Primary circuit domestic water circulator
LTP1/LTP2 : 65°C Temperature limiting safety aquastat with manual reset must be
installed on the underfloor heating outlet (not supplied)
3.6.2.1 - Pilot : 230V single-phase connection
Labels L1, L2, and L3
to be replaced with PH, PH, and PH
Fuse or
magneto-thermal
circuit breaker
Bridge to place for
230V single-phase operation
3 wire section to be defined
see table §3.3.2
Electricity supply
230V - 50Hz single-phase
see § «connecting
the pilot to the
power supply»
Firmly press the bridge into place
following the diagram below :
BAD
GOOD