16
SPRINTER MOBIL - HYMAX PRO 08.12.2015 20110005 OPI
7
Behavior in cases of error
Defective operational readiness of the system may be due to a simple error. Check the system for the
listed sources of error.
If the error cannot be removed after an inspection to the named causes, then inform customer service
or your dealer.
Problem: Motor does not start
Possible causes:
Remedy:
No power supply
Check the power supply
The main switch (2) is not switched on, or is
defective
Check the main switch (2).
Defective fuse
Have fuses checked
"LIFT" (3) button defective
Inform customer service
Motor defective
Inform customer service
Problem: Motor starts, load is not lifted
Possible causes:
Remedy:
Load is too heavy
Unload the lift
Hydraulic oil illing level is too low
Reill hydraulic oil
Emergency discharge ixture is not closed
Check emergency discharge ixture
Pressure line leaking
Inform customer service
The connector for the left is designed for a
clockwise phase order.
Your power socket may not match. One of the
phases must be swapped.
Problem: The lift cannot be lowered
Possible causes:
Remedy:
Lifting table is sitting on an obstacle
See 7.1 Moving onto an obstacle
Hydraulic valve defective
Inform customer service
"LOWER" (4) button defective
Inform customer service
Incorrect push button actuated
Push the correct push button