Troubleshooting
51
12AWFSL
The lift does
not lower when
DOWN button is
pressed
The motor does not operate
properly and does not
release the mechanical
safeties
Check the motor
The lift goes up instead of
going down
-Because solenoid air valve
is faulty
Replace air solenoid valve
-Because the air does not
reach the circuit
Verify the compressor and air
hose ability
-Because electric board is
faulty
Replace electric board
The lowering solenoid valve
does not discharge
Verify if it is powered
and check the magneto
for damages (replace if
disconnected or burnt)
The lowering solenoid valve
is not operating
Verify if it is powered
and check the magneto
for damages (replace if
disconnected or burnt)
The DOWN button is faulty
Check the DOWN button
and connection for proper
operation. Replace, if needed
The lift does
not stop at the
safety height
The safety height limit
switch is not adjusted
correctly or it is faulty
Adjust or change the limit
switch
The electric board is faulty
Clean, if necessary replace or
verify if powered and check
magneto for damage
The electric board is not
operating
Replace electric board