Installation
32
12AWFSL
7.7
Make The Electrical Hookup To Hydraulic Unit
The hookup work must be carried out by a qualifi ed electrician.
Make sure that the power supply is right. Make sure the
connection of the phases is right. Improper electrical hook-up
can damage motor and will not be covered under warranty. DO
NOT run the hydraulic unit with no oil. Damage to pump can
occur. The control unit must be kept dry.
• Make the electric hookup to the hydraulic power unit referring to the
attached wiring diagram (Figure 6) using the included cables;
• Make sure the connection of the phases is right and the lift is grounded.
7.8
Feeding Oil And Bleeding Runways
Do not install the top limit switch before bleeding the
hydraulic line. During this procedure, DO NOT attempt to raise
lift with any load.
7.8.1 Start
• Double check all nuts, bolts etc. for tightness.
Even the pre-installed
components.
• Make sure the electrical system feeding
voltage is equal to that speci
fi
ed in the
nameplate on the motor;
• Make sure the electric connections are
in compliant with diagrams (Figure 6);
• Make sure no leakage or blow-up in
hydraulic line and pneumatic line;
• Make sure the lift is grounded;
• Make sure the working area is free
from people and objects;
• Grease sliding all pivot pins;
• Pour oil in the tank (
3.5 to 5 Gallons of AW32 - AW46 Hydraulic Oil
);
• Verify that the control unit is powered by turning on the power switch;