XAS 67 - XAS 130, XATS 67 - XATS 125:
17. No air output.
a. Drive belt broken.
a. See section
Drive Belt (XAS 67 - XAS 130, XATS 67 -
Generator 110V:
18. No voltage at sockets.
a. Generator not switched on.
b. Circuit breakers are off.
a. Switch generator on.
b. Switch on circuit breakers.
19. When the electrical device is
connected, the circuit breakers switch
always off.
a. Electrical device is defective.
a. Have electrical device replaced or repaired.
20. Circuit breakers are off (down).
a. Short circuit or overload.
b. Circuit breakers switched off.
a. Remedy fault. Switch on circuit breakers.
b. Switch on circuit breakers.
21. Green lamp H3 is deactivated.
a. Circuit breakers are off.
b. Serious electrical fault.
a. Switch on circuit breakers.
b. Consult Atlas Copco.
Generator 230/400V:
22. No voltage at sockets.
a. Generator not switched on.
b. Circuit breakers are off.
a. Switch generator on.
b. Switch on circuit breakers.
23. When the electrical device is
connected, the circuit breakers switch
always off.
a. Electrical device is defective.
a. Have electrical device replaced or repaired.
24. Circuit breakers Q1 are off (down).
a. Short circuit.
b. Temperature in generator too high.
a. Remedy fault. Switch on circuit breakers.
b. Check generator cooling.
25. Green lamp H3 is deactivated.
a. Circuit breakers are off.
b. Serious electrical fault.
a. Switch on circuit breakers.
b. Consult Atlas Copco.
26. Yellow LED on insulation monitoring
relay K6 is activated.
a. Serious insulation fault.
a. Switch off the engine and restart.
Problem
Possible faults
Corrective actions