- 80 -
AIR FILTER ENGINE/COMPRESSOR
CLEANING THE DUST TRAP
To remove dust from the dust trap squeeze the
vacuator valve (6) several times.
RECOMMENDATIONS
New elements must also be inspected for tears or
punctures before installation.
Discard the element (4) when damaged.
In heavy duty applications it is recommended to
install a safety cartridge, which can be ordered with
XAS 67 - XAS 130, XATS 67 - XATS 125,
XAS 77 - XAS 150 - part no.: 2914 9309 00
XAS 97 - XAS 185 - part no.: 2914 9311 00
A dirty safety cartridge (3) is an indication of a
malfunctioning air filter element. In that case replace
the element and safety cartridge.
The safety cartridge cannot be cleaned.
REPLACING THE AIR FILTER ELEMENT
1. Release the snap clips (1) and remove the dust trap
(2). Clean the trap.
2. Remove the element (4) from the housing (5).
3. Reassemble in reverse order of dismantling. Make
sure the vacuator valve (6) points down.
4. Inspect and tighten all air intake connections.
5. Reset the vacuum indicator (7).
1. Snap clips
6. Vacuator valve
2. Dust trap cover
7. Vacuum indicator
3. Safety cartridge
(option)
8. Reset button
4. Filter element
9. Yellow indicator
5. Filter housing
(1)
(6)(2)
(3)(4)
(5)
(7)
(9)
(8)
The Atlas Copco air filters are specially
designed for the application. The use of
non-original air filters may lead to
severe damage of engine and/or
compressor element.
Never run the compressor without air
filter element.
The filter element must be cleaned or
replaced when the yellow indicator (9)
has reached the bottom of the vacuum
indicator.