- 66 -
Notes
Maintenance schedule (running hrs)
(continuation of page 65)
Daily
50 hrs after initial
start-up
Every 500 hrs
Yearly
Inspect/Adjust alternator belt
x
x
Replace alternator belt
x
x
Adjust engine inlet and outlet valves (2)
x
x
Check/Replace safety cartridge (if equipped)
x
x
Check condition of heat blanket (if necessary replace) (if equipped)
x
x
Check/Test glow plugs - grid heater
x
Test safety valve (8)
x
Measure alternator insulation resistance (on optional genset)
x
Check rubber flexibles (4)
x
Check emergency stop
x
Replace oil separator element
x
Check valve in the fuel return line (for mechanical injection system)
x
1. More frequently when operating in a dusty environment.
2. Refer to engine operation manual.
3. After a day’s work.
4. Replace all rubber flexibles every 6 years, according to DIN 20066.
5. Use Atlas Copco oil filters, with by-pass valve as specified in the parts list.
6. Gummed or clogged filters means fuel starvation and reduced engine performance.
7. See section
.
8. See section
.
9. See section
.
For other specific engine and alternator requirements refer to specific manuals.
Keep the bolts of the housing, the lifting
eye, the towbar and the axle securely
tightened.
Refer to section Technical specifications
and section Height adjustment for the
torque values.
Содержание XAS 130 DD7 C3 APP
Страница 2: ......
Страница 113: ... 113 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 115: ......
Страница 116: ......