background image

20

P

atent

 n

otiCe

No attempt has been made to determine the patent status of applications illustrated or described in this publication. 

Inclusion in  

this publication of any design or method of use, which may be patented, is not to be construed as promoting or 

sanctioning unauthorized use.

USER ASSISTANCE

WARRANTY & PRODUCT REGISTRATION 

We warrant this product to the original owner to be free from defects in material and workmanship when installed in 

accordance with Atlantic Ultraviolet Corporation

®

 specifications for a period of time as follows:

UV Water Purifier Chambers

 – Type 316 stainless steel chambers will have a Twelve (12) year Limited Warranty on the stainless 

steel chamber, from the date of original purchase while the Type 304 stainless steel chambers will have a Six (6) year Limited 

Warranty on the stainless steel chamber.

UV Air Disinfection Housing

 – Three (3) year Limited Warranty on the metal housing, from the date of original purchase.

Ballasts

 – Three (3) year Limited Warranty, from the date of original purchase.

UV Lamps, Monitoring Devices, Optional Accessories, and Other Parts

 – One (1) year Limited Warranty from the date  

of original purchase.

Within the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid and which 

are determined by us to be defective. This warranty will not apply to any product, which has been subjected to misuse, negligence or 

accident; or misapplied; or modified; or repaired by unauthorized person; or improperly installed. Warranty will be null and void if 

any of the product’s original labels are removed. This Limited warranty excludes the cost of labor.
The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of claims, including claims 

of breach of warranty, within thirty (30) days after the Buyer discovers or should have discovered the facts upon which the claim is 

based. Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a waiver of such claim.
The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or implied, 

including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described 

herein. We further disclaim any responsibility whatsoever to the customer, or to any person for injury to person, damage to, or loss 

of property or value caused by any product which has been subjected to misuse, negligence, accident; or modified or repaired by 

unauthorized persons; or improperly installed.

Under no circumstances shall the Company be liable for any incidental, consequential or special damages; losses or expenses arising 

from the contract for this product, or in connection with the use of, or inability to use, our product for any purpose whatsoever.
Be sure to register your product and validate purchase within 30 days — registration is simple and will take less than 2 minutes to do. 

NOTE

 – failure to register your purchase may jeopardize warranty.

Go to AtlanticUltraviolet.com and scroll down to the bottom of the page, under “Trust” click the “Warranty Registration Form”, 

complete and click “Submit”. Or click on “Warranty Registration PDF” to download the warranty registration card as a PDF, 

complete and mail to us at 375 Marcus Boulevard, Hauppauge, NY 11788, or simply fax to (631) 273-0771. If you prefer to register 

by phone, please call (631) 273-0500 and our customer service staff will be glad to assist you.
For your convenience, record the following information below. The model and serial number can be found on a label located

 

on the 

Sanidyne

®

 

Prime Remote

 

Portable Area Sanitizer. Keep this manual, along with proof of purchase, handy when 

 

contacting our offices.

Atlantic Ultraviolet Corporation

®

 

makes every effort to ensure that the 

Sanidyne

®

 

Prime Remote

 

Portable 

Area Sanitizer is a product of superior 

quality and workmanship. This manual 

describes the installation, operation and 

maintenance of the 

Sanidyne

®

 

Prime 

Remote

 

Portable Area Sanitizer

.

Please read and become familiar with the 

contents of this manual before installing 

or using this unit. If after reading the 

manual you still have questions, or 

concerns, regarding the installation or 

use of this unit, contact our offices, 

weekdays between 8:30 am and 5:00 pm 

Eastern Time, at:

Atlantic Ultraviolet Corporation

®

375 Marcus Boulevard

Hauppauge, New York, 11788
Tel: (631) 273-0500

Fax: (631) 273-0771
Email: [email protected]

Shop: AtlanticUltraviolet.com

Learn More: Ultraviolet.com

Purchased From:

Date:

Model:

Serial No.:

Содержание Sanidyne 40-0634C

Страница 1: ...GER 8 Lamp Models 40 0634C 120v 40 0674C 230v Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Shop Products at AtlanticUltraviolet com Learn More at Ultraviolet com ...

Страница 2: ...G 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Prime Remote Germicidal Ultraviolet Portable Area Sanitizer Questions that are not specifically answerable by these instructions should be directed to the factory Atlantic Ultraviolet Corporation takes all possible precautions...

Страница 3: ...Avoid exposure to direct or reflected germicidal ultraviolet rays Germicidal ultraviolet rays are harmful to the eyes and skin 3 Intended for indoor use only 4 Do not alter design or construction 5 Do not use this sanitizer for other than its intended purpose as described in this manual 6 Do not use this sanitizer in occupied areas The supplied DANGER DO NOT ENTER sign s MUST be clearly displayed ...

Страница 4: ...053 and 70 0011 Danger Label Hazardous Voltage 70 0053 Hg Lamp Contains Mercury Label 70 0011 Danger Label Ultraviolet Radiation 70 0052A Location of Danger Label 70 0052A on 2 Sides of Unit Post supplied Danger Signs on all access doors to the area where treatment operation will take place 8 5 x 11 2 Sided 1 Side English 1 Side Spanish 2 Supplied Item Number 98 1827 ...

Страница 5: ...n provides germicidal UV disinfection for purifying air and exposed surfaces in unoccupied areas High levels of UV C wavelengths are lethal to infectious microorganisms Ultraviolet disinfection dosage is a function of time and intensity of the germicidal UV rays to which the air and surrounding surfaces are exposed NOTE The Sanidyne Prime Remote should be used as a supplement to your facility s cl...

Страница 6: ...t all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until unit is assembled checked and confirmed The Sanidyne Prime Remote Portable Area Sanitizer includes 1 Eight lamp fixture with power cord Includes a microprocessor controller with time display and push button controls 1 Hand Held Remote Controller 8 STER L RAY High Output Ger...

Страница 7: ...and 59 4 Start Stop Button Begins treatment time countdown also used to restart Sanidyne after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to Sanidyne and will flash during Treatment Time Flashes rapidly if occupancy sensor is tripped TREATMENT TIME POWER MINUTES HOURS START STOP Treatment Time Displays HOURS MINUTES 1 Hours Button Up and Down Arrows s...

Страница 8: ...d Remote Controller all selections made to this device will require a gentle touch of a short period of time to achieve a response 1 Charging Port Charge Hand held Remote Controller using supplied AC Adapter 2 Treatment Time Set treatment time in Hours Minutes Hold finger on Treatment Time to select until menu changes to scroll bar Scroll the numbers up or down positioning the times chosen in the ...

Страница 9: ...ld Remote Controller 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Home screen pressing and holding this button will bring up a menu with choices to Power Off Reboot Airplane Mode ON OFF MUST BE SET TO ON AT ALL TIMES Additionally displays three icons ...

Страница 10: ...pplied Promate Danger Signs on all access doors to the area where treatment operation will take place It is the user s responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is off limits during treatment 3 Connect the Sanidyne Prime Remote to a properly grounded outlet power source which matches the powe...

Страница 11: ...s than 30 seconds remain on the countdown time the Sanidyne Prime Remote will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area of the Sanidyne Prime Remote Under no circumstances should this sanitizer be permitted to operate with humans plants or animals present in the Operation Area 4 Outside the Operation Area the T...

Страница 12: ...ing anywhere on the display or at the Sanidyne Prime Remote by pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Prime Remote the operator can reset the unit by pressing the START STOP button on the keypad controller again to begin the 1 30 countdown to allow all inhabitants to leave the area After the 1 30 has elapsed the unit will power on and complete the remainin...

Страница 13: ...me Remote on each side of large fixed objects like a bed or table etc 2 Measure the longest distance from the Sanidyne Prime Remote to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 4 below 3 For example if the distance from your fixture measures 15 feet find the 15 foot mark on the bar chart for each time range As the treatment time increas...

Страница 14: ...PS BETWEEN CUFFS AND GLOVES AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Prime Remote have ArmorLiteTM Safety Shield which is a protective covering over the glass of the lamp DO NOT REMOVE this covering Always disconnect power to the fixture before performing any service or maintenance Germicidal lamps ar...

Страница 15: ... factory authorized personnel Table 1 Troubleshooting Problem Possible Cause Corrective Action Sanidyne Prime Remote not operating Power disconnected Check connections Fuse not operating Remove power connector to check and replace fuse if necessary See Fuse Replacement section STER L RAY Lamp not operating STER L RAY Germicidal lamp faulty Swap suspect lamp with lamp known to be good If suspect la...

Страница 16: ... affixed to entry door s to warn that an ultraviolet sanitizer is in use and that the treatment area MUST not be entered Sanidyne is for use only in unoccupied areas Four 4 Danger Signs are included with purchase of Sanidyne Prime Remote but additional signs may be purchased NOTE Danger Signs have English on one side and Spanish on the other 5 Assure UV C Dosimeter 00 0376 A portable full featured...

Страница 17: ... No Part No 1 STER L RAY Germicidal Lamp 05 0892 2 SureliteTM Ballast 10 0138 3 Power Cord 35 1754 35 1767 4 Fuse 35 0644 35 0664 Other replacement parts are available Consult Atlantic Ultraviolet Corporation for specific requirements MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Страница 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Страница 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s ...

Страница 20: ...ies of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury to person damage to or loss of property or value caused by any product which has been subjected to misuse negligence accident or modified or repaired by unauthorized persons or improp...