7
K
eyPaD
C
ontroller
o
verview
Figure 2 – Keypad Controller Overview
1.
Treatment Time
:
Displays chosen treatment time which will countdown after start is selected. Flashes with word
“PrEP”
during Countdown Time, the word
“run”
during Treatment Time and
“donE”
when Treatment Time is completed.
2. Hour Buttons:
Up and down buttons are used to select treatment hours between 0 and 24.
3. Minute Buttons:
Up and down buttons are used to select treatment minutes between 0 and 59.
4. Start / Stop Button:
Begins treatment time countdown, also used to restart
Sanidyne
®
after an intruder is sensed in
Operating Area.
5. Power Indicator:
Glows
RED
when power is applied to
Sanidyne
®
and will flash during Treatment Time. Flashes rapidly
if occupancy sensor is tripped.
TREATMENT TIME
POWER
MINUTES
HOURS
START
STOP
Treatment Time
Displays
HOURS:MINUTES
1
Hours Button
Up and Down Arrows set
time from 0 to 24 Hours
2
Power Indicator
Glows
RED
when power
is applied, flashes during
Treatment Time
Start/Stop Button
Used to begin Treatment Time
and Restart unit after Alarm
4
Minutes Button
Up and Down Arrows set
time from 0 to 59 Minutes
3
5