15
f
use
r
ePlaCement
The fuse is contained in a small plastic tray at the bottom of the power connector.
1.
Remove the power connector from the back of the
Sanidyne
®
Prime Remote
. A screwdriver can be used to access the fuse
by inserting the blade in one of the horizontal slots and gently twisting the handle to bring the tray forward.
2. A spare fuse is accessible, clipped in front of the active fuse.
TROUBLESHOOTING
Always disconnect power to the fixture before performing any service or maintenance
.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT:
This fixture is to be serviced
ONLY
by qualified and factory authorized personnel.
Table 1 – Troubleshooting
Problem
Possible Cause
Corrective Action
Sanidyne
®
Prime
Remote
not
operating
Power disconnected
Check connections.
Fuse not operating
Remove power connector to check and
replace fuse if necessary. (See
“Fuse Replacement”
section.)
STER-L-RAY
®
Lamp
not operating
STER-L-RAY
®
Germicidal lamp faulty
Swap suspect lamp, with lamp known to be good.
If suspect lamp does not operate, replace lamp.
STER-L-RAY
®
Germicidal
lamp not properly seated
Check lamp socket and re-install lamp if necessary.
Loose Connection
Inspect for loose or disconnected wires.
Surelite
™
Ballast not operating Disconnect the fixture from utility power; then replace ballast.
Sanidyne
®
Prime
Remote
fails to
shut off
Microprocessor
assembly faulty
Wearing protective clothing and face shield, enter area, and
disconnect power to unit. Call factory for technical service.
Step 1 –
Insert
Screwdriver & Bring
Tray Forward
Step 2 –
Open Tray
(Spare Fuse is Clipped in
Front of the Active Fuse)