User’s Guide
AWP-T AWP-T1P AWP-T4P AWP-TR AWP-TR1D AWP-TR2D AWP-TR1D-T3P AWP-TRCP AWP-C AWP-TRP
Sensor with WiFi communication
Страница 1: ...www atal nl User s Guide AWP T AWP T1P AWP T4P AWP TR AWP TR1D AWP TR2D AWP TR1D T3P AWP TRCP AWP C AWP TRP Sensor with WiFi communication ...
Страница 2: ...mprovement of their products Manufacturer reserves the right to make technical changes to the device without previous notice Misprints reserved This is a User s Guide for a series of products Not all products support all features like a different types of physical measurement values Screenshots and graphics may to differ according to differences at product and computer operating system ...
Страница 3: ...PROTOCOLS 45 Modbus TCP 45 Cloud protocol JSON 48 JSON and XML via http server 52 TROUBLESHOOTING 55 Factory defaults 55 Forgotten administrator password 56 How to determine device IP address 56 How to use newly connected Digi probe 56 Error codes at channels 56 Warning exclamation mark on LCD 58 Battery symbol at LCD or wrong device time 59 Unable to power on device 59 Device is restarting contin...
Страница 4: ... SPECIFICATION 65 Power supply 65 General parameters 65 WiFi radio 65 Communication protocols 66 Parameters of inputs 67 Operating and storage conditions 74 Mechanical properties 75 End of operation 75 Declaration of Conformity 75 APPENDIX 76 REVISION HISTORY 82 ...
Страница 5: ...inimum and maximum values from device start up for each measured quantity Minimum and maximum values can be reset by the end user manually Communication via 2 4 GHz WiFi network Can be used with wireless infrastructure which is already available at place of installation Device is equipped by USB C connector which is used for powering of the device Same connector can be used for device configuratio...
Страница 6: ...Schematic drawing of WiFi sensor Dimensions ...
Страница 7: ...from high Fire and explosion hazard It is not allowed to use this device within hazardous areas especially those endangered by a potential explosion of combustible gases vapours or dust Device cover Never operate the device without the cover Aggressive environment Do not expose this device to aggressive environment any kind chemicals or mechanical shocks Use soft tissue for cleaning only Do not ap...
Страница 8: ... position This position is with antenna up Test WiFi signal strength at device location proper signal strength is essential for device function Signal strength can be examined by another WiFi device like a cell phone places at device location Another way to determine signal strength is using procedure described at chapter WiFi connection issues Fasten the device device can be screwed directly to w...
Страница 9: ...ews lock and keys For security reason do not install device to higher position than 2 m above floor Mounting cables and probes connect probes to the device Please follow recommended working positions for probes Do not place probes together with electric power distribution cables or devices Power on device connect power supply via USB C cable 5V DC Cable and adapter are part of shipment ...
Страница 10: ...ble WiFi on laptop or cell phone and connect to the access point with name WiFiSensor_xxxxxxxx If cell phone is used it is recommended to switch off mobile data connection Proper connection is signalised by following symbol at LCD display Open web browser and insert address of device http 192 168 3 1 Enter device settings go to the settings menu to start configuration Insert SSID and password for ...
Страница 11: ...eeds to be saved using the field Save or cancel Connected to WiFi after saving of settings device will be connected into WiFi network automatically This will be signalled by symbol CL Device IP address after connection into WiFi network the device will be assigned new IP address This IP address can be determined by pressing the MODE button or using procedures described at chapter How to determine ...
Страница 12: ...en key is pressed Feature Description Current measured value s Current measured value at device channel Units and value position at LCD display depends on each measured value Measured value position at display is not configurable by end user Screens with measured values are switched with interval 4 sec Alarm at measured value Alarm state Alarm 1 or Alarm 2 at measured value is signalised by bell i...
Страница 13: ...active Device acoustic is active now Acoustic mute Device acoustic was muted by web software or via keyboard RSSI indicator and mode Device is at client mode and connection attempt into WiFi network is under progress Device is at client mode and connected into WiFi network RSSI value is not available yet Connected into WiFi network Signal strength is poor RSSI 69 dBm Connected into WiFi network Si...
Страница 14: ...ce body are two buttons MODE and SET These buttons can be used for following actions Manual switching between Client and Access point mode Showing of device IP address Mute of the acoustic Showing RSSI value at LCD display ...
Страница 15: ...uter cell phone when is at AP mode If it is needed device can be switched from Client mode into AP mode manually by keyboard Procedure is described at chapter Keyboard When device is switched into AP mode by buttons and there is no other communication with WiFi sensor device is switched back to client mode automatically after 10 minutes Main page The Main page allows monitoring of online values fo...
Страница 16: ...oad of diagnostic file About page shows important information about the device Via About page is Library page accessible Library page contains description of communication protocols Logout option This tile is available when device security is enabled After clicking on the channel with online values details of channel are shown At this page information about minimum and maximum values with timestam...
Страница 17: ...tom part of the device Temperature probe is part of shipment and may to be detached from device body Device should be located into measured environment directly AWP TR ____________________________________________ Compact thermometer hygrometer This model is designed to measurement of temperature and relative humidity from probe connected to bottom part of the device Probe is a part of shipment and...
Страница 18: ... is suitable for monitoring places where probes are placed only and device body is located outside the measured environment Maximum recommended length of each probe is up to 15 m AWP TR1D ____________________________________________ Thermometer hygrometer for one external probe This model is designed to measurement of temperature and relative humidity from one Digi E probe Probe is not a part of s...
Страница 19: ... environment AWP TR1D T3P ____________________________________________ Thermometer hygrometer for one external probe and for three additional external Pt1000 temperature probes This model is designed to measurement of temperature and relative humidity from one Digi E probe and temperature from up to three Pt1000 C probes Probes are not a part of shipment and can be ordered separately It can be sel...
Страница 20: ...arometric pressure can be measured as absolute or compensated to the sea level Device should be located into measured environment directly AWP TRP ___________________________________________ Compact sensor with temperature relative humidity and barometric pressure measurement This model is designed to measurement of temperature relative humidity and barometric pressure Temperature and relative hum...
Страница 21: ...___________________________________ Compact sensor for measurement of CO2 concentrarion This model measure CO2 concentrarion of the air from internal sensor Device should be located into measured environment directly ...
Страница 22: ...ept inside temporary memory Settings changes are applied after saving Settings are saved under menu item Save or cancel Same field is used to discard changes done during configuration session Only one configuration session is possible concurrently That means setup from other places is blocked when configuration session is started Access is possible again when configuration session is saved or canc...
Страница 23: ...hown by the tile with transparency at channel page Feature is globally enabled Feature is globally disabled General settings General settings of the WiFi sensor allows for device name change setup LCD display set current time enable security and change language LCD display can be disabled if needed When LCD display is disabled measured values are not shown on display but after the button is presse...
Страница 24: ...off Current time can be synchronised with time at the computer or cell phone using option the Synchronize time Time zone UTC offset is set automatically after time synchronizing Change of device time is applied after saving whole settings Be aware that improper changing of time zone without proper changing current time can cause wrong data interpretation at ATAL Onlinesensor history ...
Страница 25: ...curity when device is used at the final deployment When security is enabled web server is switched to https mode automatically Due to natural behaviour of https and certificates at local networks it may to be needed assign security exception at web browser ATAL root certificate can be obtained on request Be aware in case of administrator password is lost device need to be restored by Factory defau...
Страница 26: ...the list Dew point Absolute humidity Specific humidity Mixing ratio Specific enthalpy or Humidex Barometric pressure units can be switched between units hPa kPa mBar mmHg inHg inH2O PSI or oz in2 Ambient pressure option is available at devices without barometric pressure sensor Value is used for calculation of Specific humidity Mixing ratio and Specific enthalpy On the devices with barometric pres...
Страница 27: ...e deactivated separately if needed Channel name can be changed according needs In case of channel name is left blank default channel name according to selected language is used Be aware that after changing channel name a new channel is created inside ATAL Onlinesensor or ATAL Database Each channel can have two independent alarms thresholds which can be configured separately Measured values can be ...
Страница 28: ...e set by Delay option Alarm state is cleared when measured value returns under set limit with selected Hysteresis When alarm is activated it can be acoustic or optical LED signalisation activated Alarm on channel can be activated optionally when measurement error on channel occurred WiFi sensors have capability to send email in case of alarm on channel is activated Up to four email recipients can ...
Страница 29: ...0 with delay 10 sec and hysteresis 2 At the beginning is alarm not activated because measured value does not exceed limit value for whole delay time After that is alarm activated because measured value was above limit for longer time than is set delay Alarm state persists till measured value goes under limit with hysteresis 50 2 48 ...
Страница 30: ...be enabled when some correction of measured values is needed Enabling this option does not affect calibration of Digi probes or device itself Alarms settings Alarm setting page allows for globally enable or disable audible and optical LED signalisation There is option to enable local or remote mute of as well ...
Страница 31: ...larms may to be intended for different person than is responsible for alarms from measured values There are three system alarms System alarm from measurement error on channel system alarm from configuration error and error from RTC battery System alarm from measurement error is activated in case error state on any of channels occurs and this error persists for selected delay Acoustic and LED signa...
Страница 32: ...blank device is automatically switched into AP mode and stay at this mode At newly purchased device is SSID filed blank Supported security modes are Open WPA WPA WPA2 PSK WPA2 PMF and WPA3 LAN Setup of LAN parameters for Client mode It can be used static IP address or IP address can be obtained from DHCP server automatically By default is DHCP option enabled In case of static IP address need to be...
Страница 33: ... needed When device is switched into AP mode by buttons and there is no other communication with WiFi sensor device is switched back to client mode automatically after 10 minutes SSID security and channel number can be changed according needs By the default SSID contains device serial number and WiFi network security is not used It is recommended to enable security for AP mode to prevent unauthori...
Страница 34: ...68 3 2 192 168 3 128 DHCP lease time 4096 sec Advanced networks Advanced networks menu allows to setup of additional wireless features Power mode feature allow to adjust power consumption and latency at WiFi client mode At high performance mode have device higher power consumption and latency of network communication is lower Normal performance mode decreases power consumption Normal performance m...
Страница 35: ... performance AWP T4P High performance AWP TR1D High performance AWP TR2D High performance AWP TR1D T3P High performance AWP C High performance AWP T Normal performance AWP TR Normal performance AWP TRCP Normal performance AWP TRP Normal performance ...
Страница 36: ...n to SMTP server need to be properly set Information how to set SMTP parameters can provide network administrator SMTP server address and port need to be set according to used server When SMTP authentication is used it needs to be set Username and Password Username is commonly same as address of email sender When encrypted communication with server is used it can be enabled TLS or STARTTLS feature...
Страница 37: ...h can be for each type of email enabled independently It can be set email at text or html format according needs Alarm repeat interval can be selected at range 10 min to 12 hours In case of this option is enabled emails are sent repeatedly to recipients if alarm state at channel persists Keep alive emails can be sent to selected recipients at interval 1 hour to 12 hours if needed ...
Страница 38: ...aiting Sending of testing email is under progress Please wait Successfully sent Testing email was successfully sent via SMTP server Please check your inbox Error 1 DNS resolve error Please make sure that is set proper address for SMTP server and IP address of DNS server is correct Error 2 Unable to create socket Please contact support Error 3 Unable to open TCP TLS connection to SMTP server Please...
Страница 39: ...ing RCPT TO commands Error 11 Error during sending DATA command Error 12 Error during sending data of email message Error 13 Error during sending end of the data dot command Error 14 Error during sending QUIT command Error 15 Authentication error It likely that was set wrong username or password Please make sure that is set proper e mail sender address Sender email address is commonly same as user...
Страница 40: ... enabled Protocol may be disabled if is not used Modbus TCP registers are described at chapter Modbus TCP HTTP server Measured values can be obtained by HTTP GET requests sent to http server running at WiFi sensor at TCP port 80 Values can be provided in XML or JSON format via files values xml and values json Feature is independent on device security and can be enabled according needs Detail infor...
Страница 41: ...TAL Onlinesensor and ATAL Database User server ATAL Onlinesensor mode By enabling this mode device sends current readings directly into ATAL Onlinesensor ATAL Onlinesensor is a paid service Each WiFi sensor comes with 3 moths free trial period for ATAL Onlinesensor It allows to test features of ATAL Onlinesensor without any additional costs For the device to be visible at ATAL Onlinesensor it need...
Страница 42: ...llowed 30 days trial version of ATAL Database is available Device settings required to proper connection into ATAL Database is described at manual for ATAL Database Sending interval can be adjusted at range 10 sec to 12 hours Enabled feature of Asynchronous messages allows to send messages when alarm occurred or is cleared Memory for unsent readings can be deactivated if needed By disabling this f...
Страница 43: ... Please wait Successfully sent Message was successfully delivered and confirmed by the server Error 1 Request was not sent because device is not at connected Client mode In case of device is at AP mode testing message cannot be sent Error 2 DNS resolve error Please make sure that is set proper URL for Cloud server and IP address of DNS server is correct Error 3 Unable to create Cloud socket Please...
Страница 44: ...pposite side is running http s server Error 6 Missing parameter Result at response It seems that at opposite side is running http s server but is not able to process communication from device Error 7 Missing confirmation True at Result parameter Error 8 Unable to send message Cloud protocol is not enabled or wrong URL for Cloud server ...
Страница 45: ...ds 16 bit register s Table with Modbus registers Depending on used communication library it may to be required insert register number s Number of the register is an address of register plus one e g register with number 0x9C41 have the Modbus address 0x9C40 Inside Modbus TCP frames are physically send address Variable Address HEX Address DEC Type Device identification Serial number device serial nu...
Страница 46: ...079 INT X Max value for channel 1 Max value for channel 8 0x9C90 0x9C97 40080 40087 INT X Type of variables Type Description BCD Register is at BCD format 16bit HEX Number at HEX format 16bit INT Register is a signed 16bit integer with range 32768 to 32767 INT X Register is a signed 16bit integer From the reason to increase resolution of transferred value is measured value multiplied by value X Nu...
Страница 47: ...emperature 1 10 C or F 125 12 5 C Relative humidity 1 10 RH 80 80 1 RH Dew point Absolute humidity Specific humidity Mixing ratio Specific enthalpy Humidex at C 1 10 C or F g m3 g kg g kg kJ kg 93 9 3 C 85 8 5 g m3 76 7 6 g kg 78 7 8 g kg 445 44 5 kJ kg 258 25 8 Barometric pressure 1 10 2 100 1 10 1 10 2 100 1 10 3 1000 1 10 hPa kPa mBar mmHg inHg inH2O PSI oz in2 10117 1011 7 hPa 10117 101 17 kPa...
Страница 48: ... re sent again at next connection Messages from memory cache are send first Size of memory cache is around 900 messages and is cleared after changing device setup Device uses HTTP 1 1 transfer That means via one TCP connection can be sent multiple POST requests multiple JSON messages In case of server is not capable to properly serve this behaviour memory cache feature needs to be deactivated Resp...
Страница 49: ...ription JsonType INT Type of the JSON message For a WiFi sensors is set to 2 JsonVersion INT Version of JSON message At present time is set to 1 OrderId INT 0 32bit unsigned Order number of messages from device restart First message is set to 0 MsgType INT 0 4 Message type 0 first message after restart 1 first message after changing config 2 synchronous message 3 asynchronous message 4 testing mes...
Страница 50: ...umber ConfID STR 15B length Configuration unique ID X YYYYYYYY ZZZZ Interval INT 0 65535 Sending interval in sec Time Date and time Now STR RFC3339 Time when message was transmitted to server Sample STR RFC3339 Time when message was sampled it can be older then Now due to sending message from cache IsValid INT 0 1 Indication if time is valid 1 RTC time is valid Rssi RSSI Received signal strength i...
Страница 51: ...arm disabled 1 lower than limit 2 higher than limit _AlMode1 INT 0 2 Alarm 1 mode _AlMode2 INT 0 2 Alarm 2 mode JSON field AState Reg is a status of the device at moment when values were sampled Description of the status bits Bit Description bit0 bit1 RSSI level indicator 0 poor signal 1 sufficient 2 good 3 excellent bit2 bit4 Unused bit5 WLAN co processor error 1 bit6 Internal hardware error 1 In...
Страница 52: ...r response HTTP 1 1 200 OK Date Thu 02 Jul 2020 08 04 30 GMT Content length 75 Result true Message All is OK Message was successfully processed JSON and XML via http server Measured values can be obtained by HTTP GET requests sent to http server running at WiFi sensor at TCP port 80 Values can be provided in XML or JSON format via files values xml and values json Feature is independent on device s...
Страница 53: ... unsigned Current device time as Unix timestamp seconds since 01 01 1970 synch INT 0 1 Indication if device time is valid 1 time is valid rssi INT 0 Received signal strength indication at dBm acc INT 0 1 Acoustic active 1 ch1 ch8 Element with information about each channel with current measured values Description of tags for channels Parameter Type Range Description name STR 32B length Name of the...
Страница 54: ...ent device time as Unix timestamp seconds since 01 01 1970 synch INT 0 1 Indication if device time is valid 1 time is valid rssi INT 0 Received signal strength indication at dBm acc INT 0 1 Acoustic active 1 ch name STR 32B length Name of the channel at English language unit STR 16B length Unit of the channel value STR 32B length Measured value at string format e g 12 8 n a ErrorX alarm1 INT 0 1 A...
Страница 55: ... lid 3 Change jumper position from Position 1 to Position 2 as shown at image below For changing jumper position may to be used tweezers 4 Connect power supply by the USB C connector 5 Wait till be shown text DEF1 DONE at LCD display 6 Disconnect power supply 7 Move jumper back to Position 1 8 Close device lid and put back all four screws 9 Power on device Factory defaults restore procedure was ac...
Страница 56: ...ture WiFi sensor needs to be connected to that platform Web interface of the infrastructure access point router can show IP address when device is at Client mode and DHCP is used This may to vary according to model of access point router How to use newly connected Digi probe When Error 30 Error 40 or text n a is shown at channel after connection new Digi probe it means that Digi probe need to be d...
Страница 57: ...elative humidity sensor inside Digi probe It is likely that relative humidity sensor is damaged Please restart device by disconnecting from power source If error state persists replace Digi probe Error 16 Measurement error from relative humidity sensor Please restart device by disconnecting from power source If error state persists replace Digi probe Error 20 Unable to read calibration constants f...
Страница 58: ... shown due to overflow during conversion Error 53 or n a Value is not available This error is shown at disabled channels or when value was not measured yet CO2 concentration is available 15 sec after device start up Error 55 This error is related to values transferred via Modbus TCP It signalises overflow of Modbus register Warning exclamation mark on LCD Warning exclamation mark shown on left bot...
Страница 59: ...ny damage Please make sure that jumper header inside device at left top corner connects middle and bottom pin For other help please contact technical support Device is restarting continuously During device restart are all segments of LCD display light up When device is continuously restarting it commonly means that power adapter or USB cable is damaged Please exchange cable and power adapter Speci...
Страница 60: ...ficient position of the device or position of infrastructure access point should be changed Adding additional access point near to device may to be solution to coverage issues as well Usage of WiFi device at places where is installed many access points with overlapping channels may to be problematic In this case you should use least occupied WiFi channel Usage of such channel will minimise potenti...
Страница 61: ...l boxes metal chambers are performed it is recommended to place the device outside and leaving only the sensors and probes inside the measured environment Such device position will improve operation reliability improve WiFi signal strength and allow to use LCD display outside chamber Positioning of temperature sensors These sensors should be placed in locations where sufficient air circulation is ...
Страница 62: ...the device including cover integrity a condition of connectors Check of the cabling and probes It should be inspected cable connections cable surface integrity and proper cable routing e g installation of new high voltage or high current cables parallel to the device cabling Check of all probes and sensing elements Visual inspection for a water ingress into probes Check location where is probes pl...
Страница 63: ...ed to enable WPA2 security with strong password as possible for AP mode Device does not use UPnP feature by any kind List of ingress ports at device you find at Appendix 5 Infrastructure security At final deployment are WiFi sensors connected to infrastructure access point or router with WiFi capability It is recommended to connect WiFi sensors into separate WiFi network with own SSID This WiFi ne...
Страница 64: ... included with product It is recommended to send diagnostic file downloaded from device when you send support request Diagnostic file can be downloaded at menu Advanced options Service Diagnostic file contains important technical information about function of device If may to contain confidential information like an IP addresses or SSID It does not contain passwords Warning Do not try to repair th...
Страница 65: ... USB C length 1 m Connector USB C General parameters Measurement interval 1 sec 15 sec for a CO2 concentration measurement USB interface USB 1 1 and USB 2 0 compatible with USB C connector LCD display switching interval 4 sec Realtime clock With internal backup battery with deviation max 200 ppm 5 ppm year at temperature 23 C 10 C WiFi radio Frequency 2 4 GHz Standard IEEE 802 11 b g n Max transmi...
Страница 66: ... with TLS version 1 2 Up to four connected clients to webserver simultaneously Port forwarding from 80 to TCP port 81 HTTP or 443 HTTPS Supported browsers Mozilla Firefox Google Chrome Microsoft Edge Internet Explorer is not supported SMTP Email Supported authentication AUTH LOGIN Supported encryption TLS STARTTLS OAuth 1 0 or 2 0 is not supported Cloud protocol HTTP S POST with JSON data HTTP S 1...
Страница 67: ...ensor Pt1000 3850 ppm 150 C to 600 C for option AWP T1PF Measurement current 250 uA Input accuracy without probes 0 2 C the at range below 100 C 0 2 from measured value at range above 100 C Overall measurement accuracy of device with connected probe is composed from accuracy of input and accuracy of used probe Probe connection Two wire connection with capability for deviation compensation due to r...
Страница 68: ...sured value at range above 100 C Overall measurement accuracy of device with connected probe is composed from accuracy of input and accuracy of used probe Probe connection Two wire connection with capability for deviation compensation due to resistance of uses cable Connection is done via CINCH RCA connector Connection is described at Appendix 2 Recommended length of probe Pt1000 C is up to 15 m L...
Страница 69: ... 1 8 RH at temperature 23 C and humidity range 0 RH to 90 RH hysteresis 1 0 RH non linearity 1 0 RH temperature error 0 05 RH C at range 0 C to 60 C Dew point temperature 1 5 C at ambient temperature T 25 C and RH 30 RH Please see chart at Appendix 1 for detail information Detail accuracy of other humidity quantities is stated there as well Response time at air flow 1 m s Temperature t90 1 min for...
Страница 70: ...ture 0 1 C Relative humidity 0 1 RH Recommended calibration interval 1 year according to used probe AWP TR2D ___________________________________________ Measured values 2x Temperature and relative humidity from external probes Digi E Other humidity quantities are calculated from the measured temperature and humidity Range accuracy and response time See manual for a particular Digi E probe s Probe ...
Страница 71: ...e 90 C to 260 C sensor Pt1000 3850 ppm 150 C to 600 C for option AWP TR1D T3PF Measurement current 250uA Pt1000 C input accuracy without probes 0 2 C the at range below 100 C 0 2 from measured value at range above 100 C Overall measurement accuracy of device with connected probe is composed from accuracy of input and accuracy of used probe Pt1000 C probe s response time According used probe Pt1000...
Страница 72: ...n 0 to 5000 ppm optionally 0 to 10000 ppm Dew point temperature 60 C to 60 C Accuracy Temperature 0 4 C Relative humidity sensor accuracy 1 8 RH at temperature 23 C and humidity range 0 RH to 90 RH hysteresis 1 0 RH non linearity 1 0 RH Barometric pressure 1 3 hPa at temperature 23 C CO2 concentration in the air 50 0 03 measured value ppm CO2 at 23 C and 1013 hPa temperature dependency in range 20...
Страница 73: ...ion of air Range 0 ppm to 5000 ppm range 0 ppm to 10000 ppm as option Accuracy 50 0 03 measured value ppm CO2 at 23 C and 1013 hPa temperature dependency in range 20 to 45 C is typ 1 measured value 1000 ppm CO2 C Response time at air flow 1 m s t90 2 min Resolution 1 ppm Recommended calibration interval 5 years AWP TRP ___________________________________________ Measured values Temperature and rel...
Страница 74: ... T 25 C and RH 30 RH Please see chart at Appendix 1 for detail information Detail accuracy of other humidity quantities is stated there as well Response time at air flow 1 m s Temperature t90 1 min for temperature step 20 C Relative humidity t90 6 sec for a 60 RH step at constant T Barometric pressure t90 44 sec Resolution Temperature including dew point temperature 0 1 C Relative humidity 0 1 RH ...
Страница 75: ...f operation In case of device decommission be aware that device may to contain confidential information like a password s From this reason is recommended do Factory defaults procedure before putting device into electronic waste Disconnect power supply from the device and dispose device as an electronic waste The device contains integrated primary lithium battery with capacity 48 mAh Declaration of...
Страница 76: ...f dew point and other humidity quantities Dew point temperature Accuracy 1 5 C at ambient temperature T 25 C and RH 30 RH Range 50 C to 60 C Absolute humidity Accuracy 1 5 g m3 at ambient temperature T 25 C Range 0 g m3 to 130 g m3 ...
Страница 77: ...mperature T 25 C Range 0 kJ kg to 450 kJ kg Humidex Range Index is relevant when temperature is in the range of 21 C to 43 C and outdoor humidity is 20 RH or above Accuracy 2 0 ºC Computed value of the humidity quantity depends on barometric pressure At devices which are not equipped by the internal atmospheric pressure sensor is constant value of the barometric pressure configured at the settings...
Страница 78: ...es uses CINCH RCA connector Connection of for AWP T1P AWP T4P Pt1000 probe is shown below Appendix 3 Connection of the Digi E probe s connector Digi E probe is connected by 4 pin M8 ELKA 4008V connector Colour coding of wire connection for AWP TR1D AWP TR2D is shown at image below ...
Страница 79: ...n be activated from two different sources It can be activated from alarms on channel and from system alarms To be device acoustic functional it needs to be globally enabled and enabled alarm source as well Mute for device acoustic can be done locally via button SET at device or from web pages software Both ways for mute are independently configurable ...
Страница 80: ...sors LED signalisation can be activated from two different sources It can be activated from alarms on channel and from system alarms To be device LED signalisation functional it needs to be globally enabled and enabled alarm source as well Mute feature for LED signalisation is not available ...
Страница 81: ...et current values via values xml and values json as well TCP 81 HTTP webserver TCP 443 HTTPS webserver when device security is enabled TCP 502 Modbus TCP port default port TCP 10001 Communication with software ATAL Vision or WifiSensorUtility default port UDP 5353 mDNS discovery protocol UDP 30718 ATAL discovery protocol Note ICMP Echo ping is enabled at WiFi sensors ...
Страница 82: ...Revision history Document version Date Note IE WFS Wx7xx 01 February 2021 Initial document version for firmware version 10 0 2 0 Note Page numbers may to differ between document versions ...