Above a 90 cm ATAG oven or an oven of another make without
casing cooling.
Fit a heat-resistant (85 °C) plate to screen off the hob. Ensure that the
space between the hob and the protective plate is ventilated. This space
must not be connected with the space above the oven.
The space between the underside of the hob and the top of the protective
plate must be at least 25 mm.
Sealing tape
Stick the sealing tape on the underside of the edge.
Don’t stick the sealing tape around the corner; rather cut four pieces to
fit effectively in the corners.
Turn the hob over and allow the appliance to sink into the opening.