2.5.3. Switch for multi-asycube connection
Depending on the configuration (number of asycube and camera) a switch is necessary to
communicate with all asycubes. The switch is compatible with DIN rail. The power supply is not
delivered by Asyril, but the connector is present on the device.
Characteristic
Value
Input Voltage
12 to 48 VDC, 18 to 30 VAC
Input Current
0.12 A @ 24 V
Connection
1 removable 3-contact
terminal block
Dimensions
24.9 x 100 x 86.5 mm
Figure 2-28: Dimensions of the switch for asycubes
2.5.4. Calibration plates
Calibration is used to:
-
Define the camera vs feeder orientation
-
Reference the field of view to the robot workspace
-
Work in millimetres in the field of view instead of pixels.
Different calibration plates can be provided by Asyril for the Asycube 50 and 80, see below.
NOTE :
There are different ways to perform the calibration depending on your application, please contact Asyril
to define the corresponding tooling if necessary.
2.5.4.1. Metric calibration
This plate is available for Asycubes 50 and 80 only.
Figure 2-29: Asycube pixel-mm calibration plate