SmartSight
Operating Manual
© Copyright Asyril S.A.
Description
Version: C
000.100.530
12/50
Detail detection
Detail localisation
¼ px accuracy
Table 2-3: Detection limit
The pixel-millimetre conversion depends on the field of view as well as the resolution of the camera.
This value is resumed in Table 2-1 for each vision kit.
2.2.2. General specifications
2.2.2.1. Control unit
The control unit is delivered with OS and software configured and ready to be used. The Cognex dongle
key, delivered in the package, has to be connected all the time to allow correct function of the system.
Figure 2-4: control unit
Characteristic
Value
Dimensions [mm]
See Figure 2-20
Power supply
24VDC / 75 W
Windows protection
The Control Unit (partition C) is protected with the EWF from
WindowsEmbedded. When enable, the Control Unit can be turned off without
shutdown (No UPS is needed). Any changes on the partition C: will be erased
at the next restart of the pc.
Note that the partition D: is not protected, as recipes must be saved on it. For
this reason, switching off the control unit during, or close after, a recipe saving
operation might corrupt the data.
Backup
The system partition and the data directory of the Control Unit are saved on a
CF card placed inside the control unit. This backup can then be used to restore
as fast as possible the system in case of a system failure (Harddisk failure). A
backup is created at delivery time and can be launched manually at any time.