SmartSight
Operating Manual
© Copyright Asyril S.A.
Description
Version: C
000.100.530
29/50
a camera with 4 outputs (non-standard). Ask Asyril sale office to order this component.
2.3.3.7. External light 1 and 2 connections
A standard M12 4-pins cable enables to
connect to the external light, it must be
connected as follows :
Pin
Signal
(1)
24VDC
S-Power (max. 3.5A)
(2)
0V GND S-Power
(3)
0V GND S-Power
(4)
24VDC pulse (max.3.5A)
(5)
Not wired
Connector type (on EasyConnect Box side) :
M12, 5P, female
Figure 2-19 : External light 1 and 2
NOTE :
If the external light have a power connection and a command connection (4 wires), use pins 1 and 2 for the
power (3.5A max.) and 3 and 4 for the command.
If the external light have only a power/command signal (two wires), use the pins 3 and 4 (3.5A max.).
WARNING !
-
To use the backlight synchronisation of the Asycube 2 and/or the external light 2, you need
a camera with 4 outputs (non-standard). Ask Asyril sale office to order this component.
(3)
(1)
(4)
(2)
(5)