background image

Installation Steps

1.  Mount Illuminator

2.  Connect Illuminator to low voltage  

power supply 

3.  Input 12-24V DC/ 24V AC

Optional Set-up (if required)

4.  Adjust Power to alter light intensity

5.  Adjust Photocell sensitivity

 

6.  Photocell following contact

RM/RL F 100 Setup

7.  Telemetry input and photocell 

following contact

Set Up Steps

1.  Position illuminator adjacent to 

camera and point towards scene 

2.  Adjust vertical and horizontal  

position of lamp to ensure full field  

of view illuminated

3.  Tighten all fixings

Package Contents

1.  Illuminator including mounting 

bracket

  (RM/RL F 100 only, includes 

additional wiring loom)

illuminators installation guide

RAYMAX / RAYLUX  

FUSION illuminator

Overview

This installation guide provides instructions for installing the RAYMAX  

and RAYLUX FUSION series illuminators

FUSION

GOLDeN RULeS:

•  Ensure operating voltage is 

 

correct for unit being installed 

  (12-24V DC/ 24V AC)

www.rayteccctv.com

Version: 2

Summary of Contents for RL F 25

Page 1: ...amera and point towards scene 2 Adjust vertical and horizontal position of lamp to ensure full field of view illuminated 3 Tighten all fixings Package Contents 1 Illuminator including mounting bracket...

Page 2: ...owing contact Power adjust Power in Made in UK P cell adjust Telemetry P C Contact Back of Unit Command and Control Technology DC AC Black wire Red wire DC AC Black wire Red wire RM RL F 25 50 Cables...

Page 3: ...ontact volt free relay contact normally open day to normally closed night Clockwise more sensitive Anticlockwise less sensitive RM RL F 25 50 only Orange and brown wires Photocell following contact RM...

Page 4: ...illuminator adjacent to camera and point towards scene Optional night set up for optimum image performance 4 Reduces performance May cause hot spots Best performance Camera 1 Adjust vertical and horiz...

Page 5: ...rawings Not to scale Standard Bracketry Optional Bracketry 25mm 1 12 5mm 0 5 47mm 1 9 RM RL F 25 25mm 1 36mm 1 4 72mm 2 8 RM RL F 50 25mm 1 52mm 2 104 5mm 4 1 RM RL F 100 Wall Mount Dome Mount Ptz Mou...

Page 6: ...mption 35W max 25W max 12W max Input 12 24V DC 24V AC 12 24V DC 24V AC 12 24V DC 24V AC Current 2 6A 12V or 1 3A 24V 1 5A 12V or 0 75A 24V 1A 12V or 0 5A 24V Weight 1 4kg 1 0kg 0 5kg Environment IP66...

Page 7: ...eck lamp current remove ve red lead from power supply and connect multimeter set to 10A in line with the lamp One lead of multimeter in common COM other lead into 10A socket of multimeter set multimet...

Page 8: ...UK Europe T 44 0 1670 520055 F 44 0 1670 819760 sales rayteccctv com Americas Toll Free T 1 888 505 8335 ussales rayteccctv com www rayteccctv com...