Specifications
41
7 Specifications
Overview
The specifications below are intended as a convenient reference for personnel involved with installation,
operation, and maintenance of the DV-7000 and DV-8000 Heli-Flow Pump.
Safety First
Familiarity with the performance specifications in this section can provide information leading to safe
operation of the Pump. For additional safety information, refer to the
Safety
section.
Specifications
Table 7-1 contains the technical specifications for the DV-7000 and DV-8000 Pumps. If you have any
questions about these specifications or pump performance, contact Asymtek Technical Support or your
authorized distributor.
"
NOTE
The specifications below are applicable to both the DV-7000 and the DV-8000 unless
otherwise indicated.
Table 7-1 Pump Specifications
Parameter
Specification
Dimensions
Length:
190 to 192 mm (7.48 to 7.56 inch)
Width:
33 mm (1.3 inch)
Depth:
72.6 mm (2.86 inch)
Weight (dry, without syringe):
362 g (0.8 pound)
Operating Voltage:
24 VDC
Operating Air Pressure (max):
With Feed Tube:
275 kPa (40 psi, 2.75 bars)
With Elbow Fitting:
551 kPa (80 psi, 5.5 bars)
Syringe Sizes:
5, 10, 30, 74, or
177
cc
(0.17, 0.34, 1.0,
2.5,
or
6.0 ounce
)
Motor Type:
Closed-loop velocity control with encoder
feedback
Maximum Tolerable Board Warpage:
(DV-7000 only)
1.58 mm (0.06 inch)