Installation
15
a. In the Setup Valves dialog box, click on
Edit
(Figure 3-16).
b. In the Settings dialog box, click on the
Settings
tab and click on the radio button next to
Constant syringe pressure during dispensing
(Figure 3-17).
!
Activating this feature means that a constant supply of air pressure will be applied to the
syringe as opposed to the air toggling ON and OFF as needed. A constant air supply
can result in more a consistent dot size.
c. Click on the
Floating Head
tab and click in the box next to
Enable Floating Head
. A
checkmark in the box indicates the feature is enabled (Figure 3-17).
d. Enter a value for the Floating Head Z Overtravel.
!
The “Floating Head Z Overtravel” is a Z-axis value that determines how far below the
programmed dispensing height the dispensing head will travel in search of the substrate.
This feature ensures a consistent dispensing height even if the workpiece is warped.
The maximum value is 0.08-inch (2 mm). Typically, 0.04-inch (1 mm) is sufficient.
e. Click
on
OK
to accept the new settings and close the Settings dialog box.
Figure 3-17 Enabling the Floating Head
6. In the Setup Valves dialog box, click on
OK
.
!
You will be prompted to restart Fluidmove.
7. Click
on
Yes
!
Fluidmove will restart and you will be prompted to run Valve Offsets.