Installation
Installation on Spectrum Series Dispensing Systems
1. Use the Fluidmove software position controls to move the dispensing head to the front center of
the dispensing area.
2. Perform a service shutdown and lock out/tag out power to the dispensing system as specified in
the applicable dispensing system manual.
3. Slide the dovetail bracket (included with the dispensing valve) into the valve mounting bracket on
the Z-axis face plate.
4. Secure by turning the locking lever on the valve mounting bracket to the upward position
(Figure 3-12).
5. Make valve electrical connections as shown in Figure 3-13. The syringe must be installed to
connect the clear fluid line. See "
Installing a Syringe
" in the
Operation
section.
6. Configure the Fluidmove software for the DV-7000/DV-8000 valve. See "
Software
Configuration
" later in this section.
7. After the valve has been installed, you must adjust the Height Sensor Probe. Refer to the
manual for your particular dispensing system.
Figure 3-12 Installing the Valve (Spectrum)
Figure 3-13 Valve Connections (Spectrum)