8
Installation
Installation on Century Series Systems
"
NOTE
Illustrations in this section show the DV-7000, but installation instructions also apply to
DV-8000 Series pumps.
1. Use the position controls to move the dispensing head to the front center of the dispensing area.
2. Perform a service shutdown and lock out/tag out power to the dispensing system as specified in
the applicable dispensing system manual.
3. Slide the valve into the valve bracket (Figure 3-1).
4. Use a 4 mm hex key to tighten the locking screw on the side of the valve bracket.
!
The valve should be tightly held by the bracket.
Figure 3-1 Attaching the Valve Bracket (Century Series System)
"
NOTE
If you will be using a Height Sensor, proceed with Step 5. If not, skip to Step 7.
5. Use a 3 mm hex key to attach the height sensor bracket to the valve bracket (Figure 3-2).
6. Use a Phillips head screwdriver to attach the height sensor to the height sensor bracket
(Figure 3-3).
Valve Bracket