Installation
13
Installation on DispenseMate 550 Series Dispensing Systems
1. Use the Fluidmove software position controls to move the dispensing head to the front center of
the dispensing area.
2. Perform a service shutdown and lock out/tag out power to the dispensing system as specified in
the applicable dispensing system manual.
3. Loosen the six (6) screws on the Z-axis face plate (Figure 3-14A) and slide the face plate up so
that it is flush with the Z-axis extrusion (Figure 3-14B). Tighten the screws on the face plate.
4. Slide the dovetail bracket (included with the valve) into the valve mounting bracket. Secure by
tightening the socket head cap screw on the valve mounting bracket (Figure 3-14C).
5. Make electrical connections as shown in Figure 3-15. The syringe must be installed to connect
the clear fluid line. See "
Installing a Syringe
" in the
Operation
section.
6. Configure the Fluidmove software for the DV-7000/DV-8000 valve. See "
Software
Configuration
" later in this section.
7. After the valve has been installed, you must adjust the Height Sensor Probe. Refer to the
DispenseMate User Guide
.
"
NOTES
When using the DV-7000 valve, make sure that the Valve Selector (U27) switch, located
on the main board inside the electronics pan, is set to the proper position. The default
setting is DV-8000. For detailed information, refer to the
DispenseMate User Guide
.
Figure 3-14 Installing the Valve (DispenseMate)
Figure 3-15 Valve Connections (DispenseMate)
Valve
Mounting
Bracket
Socket Head
Cap Screw
Figure A
Figure B
Figure C
Z-axis Extrusion
Z-axis
Face Plate