80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
8
6000 Series Programming Instructions:
Onboard Method
• OPEN SPEED:
Speed at which door opens.
• MAX OPEN FORCE:
Force exerted by motor to open door.
• OPEN START FORCE:
Force exerted by motor at start of
opening cycle to help overcome stack pressure or latch device.
• OPEN STALL FORCE:
Force exerted when door is slowed to
a stop while opening, with 1 being lightest and 10 being
strongest. Measure door force to ensure compliance with
standards and codes.
• ADJUST HOLD OPEN:
Time door is held at open position when
ON/OFF/HO switch is in ON position.
• HOLD OPEN FORCE:
Force exerted to hold door in max open
position. Can be adjusted to overcome stack pressure, wind, or
other forces pushing on door.
• OBST DET SENS:
Amount of time door will push against an
obstruction before stalling or moving in opposite direction.
• OPEN DELAY 1:
Time before door will begin to open once
activation has been received.
Set options.
Using joystick, set options. (Figure 14)
Continue with Input Connections on page 13
Figure 14
Max Open Force
• OPEN DELAY 2:
Time before door will begin to open once
activation has been received. Part of Vestibule functionality.
• PUSH & GO:
As door is manually opened, operator ‘senses’
movement and opens door to full-open position.
• OBSTR DURING CLOSE:
Door will reverse to open position if
it hits an obstruction while closing.
• NO OBSTR NEAR OPEN:
Used with door mounted presence
sensor. Operator will ignore obstruction input from sensor
in last 30 degrees of opening.
• NO OBSTR NEAR CLOSE:
Used with door mounted presence
sensor. Operator will ignore obstruction input from sensor
in last 10 degrees of closing.
• ENERGIZE <20°:
24V outputs will change state when door is
20 degrees from close after a manual or automatic cycle.
• AUDIBLE BEEP:
Turn audible beep feedback from interface
PCB off/on.