80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
7
6000 Series Programming Instructions:
Onboard Method
Adjust opening and closing.
Using joystick, make selections to adjust
electrical opening and closing of door.
(Figure 13)
NOTE: Latch, Sweep, and Backcheck
valves were adjusted during initial
installation so unit functions properly
as a mechanical door closer. See
Installation Instructions for your
model.
Figure 13
Open Speed
6: iiiiii----
Speed/Force and Timing/Location
settings must be adjusted to meet
ANSI BHMA A159.19 (American
National Standard for Power Assist and
Low Energy Power Operated Doors)
requirements for opening and closing
based on door weight
an
d width. (See
tables below)
Note: To determine minimum times from close to full open, the operator shall be adjusted as shown in the chart. Backcheck occurring at a point
between positions in Table II shall use the lowest setting. For example, if the backcheck occurs at 75 degrees, the full open shall be the time shown in
Table I plus 1.5 seconds.
Doors of other weights and widths can be calculated using the formula:
T = D
Ö
W
/ 133 in US Units
T = D
Ö
W
/ 2260 in SI (metric) Units
Where: T = Time, seconds
D = Door width, inches (mm)
W = Door weight, lbs. (kg)
The values for “T” time have been rounded up to the nearest half secound. These values are based on a kinetic energy of 1.25 lbf-ft.
Table I
Minimum Opening Time to Backcheck or 80 degrees (whichever occurs first) and
Minimum Closing Time from 90 degrees to Latchcheck or 10 degrees (whichever occurs first)
“D” Door Leaf Width
Inches (mm)
“W” Door Weight in Pounds (kg)
100 (45.4)
125 (56.7)
150 (68.0)
175 (79.4)
200 (90.7)
*30 (762)
3.0
3.0
3.0
3.0
3.5
36 (914)
3.0
3.5
3.5
4.0
4.0
42 (1067)
3.5
4.0
4.0
4.5
4.5
48 (1219)
4.0
4.5
4.5
5.0
5.5
* Check applicable Building Codes for clear width requrements in the Means of Egress. See Appendix for additional door weights.
Table II:
Total Opening Time to 90 Degrees
Backcheck at 60 degrees
Backcheck at 70 degrees
Backcheck at 80 degrees
Table I plus 2 seconds
Table I plus 1.5 seconds
Table I plus 1 second
If the door opens more than 90 degrees, it shall continue at the same rate as backcheck speed. Matrix values are in seconds.