6000 Series
Programming Instructions
Output Connections (Default)
Use green 2-position connectors on control board to add any necessary
outputs, such as electric strikes, mag locks, exit devices, door open
position output, etc. (Figure 20)
NOTE: Relay outputs can be customized.
Relay Outputs
The operator has two relay outputs which may be wired to external
control systems or devices. The function of each relay is selectable
depending on the needs of the installation.
The outputs are labeled RLY 1 and RLY 2 like the wiring terminal blocks on
the operator hardware.
Click Restore Defaults to set the input and output functions to factory
default, if needed. Be sure to click Save after making changes.
These are the relay output functions:
3 Second Relay
Normally open relay that closes for 3 seconds after an activation to open.
Open POS Relay
Normally open relay that closes when door is in open position.
Closed POS Relay
Normally open relay that closes when the door is in the closed position.
Door Latch Relay
Normally open relay that closes any time the door is not in the closed
position.
Figure 20
Output
Connectors