80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
32
6000 Series
Wiring Diagrams
596 Presence Detector on Single Door Opening
(change factory pre-wiring to illustration below - move NO to +24)
596 Presence Sensor
mounted to opening side
or closing side of door
(on single opening)
• Door is normally closed.
• Activating switch will open door.
• Door will close after hold open time delay has elapsed.
• If using door mounted presence sensors:
For Closing Cycle sensor (SS1) Input 4 to be set to Obstruction 1
For Opening Cycle sensor (SS2) Input 3 to be set to Obstruction 2
Alternate 24V
Source (+V and
-V of Power
Supply)
NOTE: For Low Energy Operators, Presence
Detectors and/or sensors CANNOT be used
to activate an opening cycle of the door.