6000 Series
Wiring Diagrams
Electric Latch Retraction Exit Device Powered Through 782N Controller
(change factory pre-wiring to illustration below - move GND to COM)
• Door is normally closed and latched.
• Activating switch will retract exit device
latch bolt and door will automatically
open. Door will close after hold open
time delay has elapsed.
• Exit device allows egress at all times,
including during power failures.
• Activation can be wall switch, card
reader, key switch, etc (Normally open
momentary dry contacts).
• Contact Tech Support for other devices
or manufacturer’s instructions.
• To turn on relay (Relay 2), Latch
Retraction (Output Connections, page
14) and/or Open Delay (Set options,
page 8) features must be turned on
using adjustment procedures on pages
indicated.