80-9360-1043-020 Rev 1 05/21
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
23
6000 Series
Wiring Diagrams
Electric Dogging Exit Device
(change factory pre-wiring to illustration below - move NO to +24)
• Door is normally closed and latched.
• Turning key switch ON will apply power to exit device.
• First depression on device touch bar will electrically
dog device for push/pull operation. Door will now open
automatically when wall switch is depressed. Door will
close after hold open time delay has expired.
• Device will re-latch during a power failure or when key
switch is turned off.
• Exit device allows egress at all times, including during
power failures.
• Activation can be wall switch, card reader, key switch, etc
(Normally open momentary dry contacts).
• Current draw at Power Outputs not to exceed 1.3A.
• To turn on relay (Relay 2), Latch Retraction (Output
Connections, page 14) and/or Open Delay (Set options,
page 8) features must be turned on using adjustment
procedures on pages indicated.