PANEL CONTROLS
The blowers and automatic fuel supply are controlled from
a panel on the top of the stove. The control panel functions
are a follows.
A.
ON/OFF SWITCH (“POWER” BUTTON)
When pushed, the stove will automatically ignite. No other
fi
re starter is necessary. The igniter will stay on for at least
10 and up to 12 minutes, depending on when Proof of Fire
is reached. The
fi
re should start in approximately 5 minutes.
The red light located above the “POWER” button will turn
green when pressed and remain green until the stove is turned
off.
After pushing “POWER”, the auger motor is on for 3.5
minutes, off for 1 minute. During the remainder of the start-up
period, the auger motor operates on the heat range “1” setting.
During start up the heat level advance (Up and Down keys)
will change the heat range indicator level accordingly, but
there is no change in the stoves operating conditions until
start-up is completed.
During start-up ignition must occur within 12 minutes or the
stove will error out and show E4.
During the start-up phase, the Mode key does not function.
B.
LEVEL / TEMP ARROW BUTTONS
These buttons when pushed will set the pellet feed rate,
hence the heat output or heat range of your stove.
The levels of heat output will incrementally change on the
bar graph starting from heat range “1” to heat range “5”.
C.
°C / °F BUTTON
The °C / °F button changes the two digit display from
degrees Celsius to degrees Fahrenheit.
D.
MODE (M/T) BUTTON
The Mode of the stove can be switched between manual and
controlled with a Thermostat. Separate LEDs to the left of the
two digit display indicate the mode of operation – Manual or
T-Stat. The stove has to be in normal operation to be switched
from Manual to T-Stat mode.
Manual mode operates according to the 5 set levels of feed
on the bar graph from heat range “1” to heat range “5”.
T-Stat mode works as follows:
The stove has a built in Thermostat into the controls of the
appliance. The temperature sensor for the T-Stat is located
on the back of the stove behind the display board.
Once the stove has gone into run mode the stove can be
switch into T-Stat mode.
The Up and Down Level / Temp Arrow buttons are used to
change the desired set-point temperature. Once the desired
temperature is reached the two digit display will
fl
ash for four
seconds and reset to the actual room temperature.
Once the stove reaches within 3°F of the desired temperature
set point, it returns to the heat range that the stove was set
on before it was switched to T-Stat mode (if the stove was
running on heat range “5” when switched to T-stat mode when
it gets within 3°F of the set point it will return to heat range “5”).
Once the stove reaches the desired set-point, the stove will
drop to heat range “1”.
When room temperature drops below desired set-point
the stove will ramp back up until it reaches the desired
temperature.