Installation
You have already made the important decision of choosing
your U.S. Stove Pellet Burning Room Heater; now your next
step is to determine where to install your new pellet stove
heater. To get the most ef
fi
cient use of re-circulated heat, you
should consider a room that is centrally located within your
home. Choose a room that is large and open.
It is
Extremely Important
to maintain proper clearances
from any combustible surfaces or materials in the room where
your heater will be located. You can
fi
nd proper clearance
measurements on page 12 of this manual and on the rating
label of your pellet stove.
The pellet stove can be vented through an exterior wall
or into an existing masonry or metal chimney. The chimney
must be lined if it is over 6” (150mm) in diameter or if it has
a cross-sectional area of over 28 square inches (711mm2).
Venting can pass through the ceiling and roof if approved
pipe is used. Where passage through a wall, or partition of
combustible construction is desired, the installation must
conform to CAN/CSA-B365.
DO NOT OBTAIN COMBUSTION AIR FROM THE ATTIC,
GARAGE OR ANY OTHER UNVENTILATED AREA. YOU
MAY OBTAIN COMBUSTION AIR FROM A VENTILATED
CRAWL SPACE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER HEATER, FURNACE OR APPLIANCE.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
ONLY USE APPROVED MATERIAL FOR INSTALLATION,
FAILURE TO DO SO MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
This appliance is certi
fi
ed for use with listed 3 inch or 4 inch
“PL” or “L” pellet venting products as well as Selkirk’s Direct-
Temp Vent system for pellet burning appliances. The use of
other components other than stated herein could cause bodily
harm, heater damage, and void your warranty.
HORIZONTAL EXHAUST VENT INSTALLATION
1. Locate your pellet stove in a location which meets the
requirements of this manual, but in an area where it
does not interfere with the house framing, wiring, etc.
2. Install a non-combustible hearth pad underneath the
pellet stove. This pad should extend at least 6” (152mm)
in front of the unit.
3. Place the pellet stove approximately 15” (381mm) away
from the interior wall.
4. Locate the center of the exhaust pipe of your unit. This
point should then be extended to the interior wall of
your house. Once you have located the center point,
on the interior wall, cut a 7” (175mm) diameter hole
through the wall.
5. The next step is to install the wall thimble, refer to the
instructions which come with the wall thimble for this
step.
6. Install the appropriate length of exhaust vent pipe into
the wall thimble. See steps 11 and 12 when determining
the correct length of exhaust vent to use.
7. Outside Fresh Air is Mandatory when installing
this pellet stove room heater in airtight homes and
mobile homes.
Be sure that the outside air vent has
an approved cap on it to prevent rodents from entering.
Be sure to install in location that won’t become blocked
with snow, etc.
8. The air intake pipe is equipped with a butter
fl
y valve
that is preset to maximum air intake. For optimum
operating efficiency you may calibrate the butterfly
valve to provide less intake air.
Caution: Too much
restriction on the intake air will cause dirtier burn,
therefore, will require more frequent cleaning.
9. Connect the exhaust vent pipe to the exhaust outlet of
your pellet stove.
10. Secure all vent joint connections with 3 screws. Seal the
exhaust vent joint connections with high temperature
silicone sealant.
11. Push the unit straight back to the interior wall, being sure
to maintain the minimum clearances to combustibles
6” (152mm) to the back of the unit. Seal the annular
space of the wall thimble and around the vent pipe with
high temperature silicone sealant.
12. The exhaust vent pipe must extend at least 12” (300mm)
out past the exterior wall. Seal the annular space of
the wall thimble and around the vent pipe with high
temperature silicone sealant.
13. Install an approved horizontal termination cap or if
necessary install a 90° elbow and appropriate length
of vertical venting. An approved vertical vent cap is
recommended.
11