Trouble Shooting Guide
Display is Flashing “E3”
Possible Causes
Possible Remedies: (Unplug stove
fi
rst when possible)
1. The hopper is out of pellets
Re
fi
ll the hopper.
2. The air dampener is too far open for a low feed setting
If on the low setting, you may need to close the dampener
all the way.
3. The burnpot holes are blocked.
Remove the burnpot and thoroughly clean it.
4. The air inlet, the interior chambers, or exhaust system
has a partial blockage.
Follow all cleaning procedures in the maintenance section
of the owner's manual
5. The hopper safety switch has failed or hopper is open.
When operating the unit, be sure the hopper lid is closed
so that the hopper safety switch will activate. Check the
wires leading from the hopper safety switch to the control
panel and auger motor for secure connections. Use a
continuity tester to test the hopper safety switch; replace
if necessary.
6. The auger shaft is jammed.
"Start by emptying the hopper. Then remove the auger
motor by removing the auger pin, then remove the two
bolts that hold the auger bracket to the auger tube. The
auger bracket will now be able to be removed form the
auger tube. Remove the two bolts on the side of the auger
tube to remove the lower bearing of the auger. Pull the
auger out of the tube to free the jam.
7. The auger motor has failed.
Remove the auger motor from the auger shaft and try to
run the unit. If the motor will turn the shaft is jammed on
something. If the motor will not turn, the motor is bad.
8. The Proof of Fire (POF) thermodisc has malfunctioned.
Temporarily bypass the POF thermodisc by disconnecting
the two wires and connecting them with a short piece of
wire. Then plug the stove back up. If the stove comes on
and works, you need to replace the POF thermodisc. This
is for testing only. DO NOT LEAVE THE THERMODISC
BYPASSED. Your blowers will never shut off and if the
fi
re went out the auger will continue to feed pellets until
the hopper is empty if you leave the POF thermodisc
bypassed.
9. The control board is not sending power to the POF
thermodisc or other auger system components.
There should be a 5-volt (approximately) current going
to the POF thermodisc after the stove has been on for
10 minutes.
Display is Flashing “E4”
Possible Causes
Possible Remedies: (Unplug stove
fi
rst when possible)
1. The air inlet, burnpot, interior combustion air chambers,
combustion blower, or exhaust pipe are blocked with ash
or foreign material.
Follow all cleaning procedures in the maintenance section
of the owner’s manual.
2. The Proof of Fire (POF) thermodisc has came unplugged
Check the (POF) thermodisc to see if the wires are
connected properly.
3. The Proof of Fire (POF) thermodisc has malfunctioned.
Temporarily bypass the POF thermodisc by disconnecting
the two wires and connecting them with a short piece of
wire. Then plug the stove back up. If the stove comes on
and works, you need to replace the POF thermodisc. This
is for testing only. DO NOT LEAVE THE THERMODISC
BYPASSED. Your blowers will never shut off and if the
fi
re went out the auger will continue to feed pellets until
the hopper is empty if you leave the POF thermodisc
bypassed.
27