4.10 Operating Station
The operating station houses the UP/DOWN switch and the emergency stop button. To
test or remove either of these switches, use a Phillips screwdriver to remove the two (2)
screws that secure the switch plate to the lift car and pull the plate away from the lift car.
A standard multi-meter can be used to test the switches.
To remove the rocker switch, depress the mounting tabs and push the switch out of its
mounting cutout.
To remove the emergency stop button, use the release lever on the contact block to
disengage the block from the back of the operator then pull it off. Remove the mounting
nut to free the operator from the switch plate.
Содержание VIRTUOSO 5460F