EN
AS Strömungstechnik GmbH
www.asstroemungstechnik.de
Version date: 09/2020
29
6. Check that the o-rings (1), (2) and
(3) are in place and undamaged e.g.
cracks, tears, and residue are signs of
damage.
7. Check that the locking pin (4) is in
place between the two parts of the
housing and is undamaged.
CAUTION
Danger due to leaks!
If the top and main body do not line up
this can be a sign that it has been tam-
pered with and could result in leaks.
.
Assembly/commissioning
8. Check that there is a code disk (5)
on the fill head and that the coding
matches that of the dip tube (6) and
thus the chemical. This means that
only the correct three pins (7) must be
missing and the code disk must not be
bent.
»
Do not change any coding on the dip
tube or the code disk if they do not
match. A list of the possible codings is
available on request.
9. If available, check whether the con-
nected valves and filters are free and
functional.
Содержание DH -N2 Series