RECEIPT INSPECTION
All Maturmeat® units are factory tested for performance and are free from defects when
shipped. The utmost care has been taken in crating this product to protect against damage in
transit.
You should carefully inspect your Maturmeat® unit for damage during delivery, even if the crate
is free from damage. If damage is detected, you should save all the crating materials and make
note on the carrier’s Bill Of Lading describing this. A freight claim should be filed immediately. If
damage is subsequently noted during or immediately after installation, contact the respective
carrier and file a freight claim. Under no condition may a damaged unit be returned without first
obtaining written permission (return authorization).
1.6
INSTALLATION
DANGER
Excessive Weight Hazard
Use two or more people to move
and install your Maturmeat®.
Failure to do so can result in back
or other injury.
LOCATION:
Select a proper location away from extreme heat or
cold. Space above the unit should allow for breath-
ability to the condensing unit and access to the Water/
Aroma tanks. Allow enough clearance between the
unit and the side wall in order to allow the doors to fully
open.
PACKAGING:
The unit is shipped from the factory strapped to a stur-
dy wooden pallet and protected by MDF crating. The
crating is attached to the pallet with nails and several
screws. These should first be removed to avoid scratch-
ing the unit when lifting off the crating. To remove the
Maturmeat® from the wooden pallet start by cutting
free the nylon bands. There are 4 bolts connecting the
Maturmeat® to the pallet, remove them to release the
Maturmeat® from the pallet.
Most exterior surfaces have a protective vinyl covering
to prevent scratching during manufacturing, shipping,
and installation, remove after installation and discard.
NOTE: DO NOT LAY THE UNIT ON ITS SIDE/BACK/FRONT
DURING TRANSPORTATION OR INSTALLATION.
POWER CORD:
An attached power cord is provided without plug,
shipped coiled inside the compressor compartment.
For your safety and protection, have the installer con-
nect the proper plug for your country by checking with
the information on the data plate. Connect only to an
appropriate dedicated 20 amp outlet.
DANGER
Electrical Hazard
Never connect power to unit
via extension cord or adapter,
this can cause damage to the
system and/or start a fire.
POWER SUPPLY:
The supply voltage should be checked prior to connec-
tion to be certain that proper voltage for the cabinet
wiring is available (refer to the data plate for the correct
unit voltage). Make connections in accordance with lo-
cal electrical codes. Use qualified electricians.
Use of a separate, dedicated circuit is required.
Size wiring to handle indicated load and provide neces-
sary overcurrent protector in circuit (see amp require-
ments on the unit’s data plate).