![Argus Copper Box v4 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/argus/copper-box-v4/copper-box-v4_manual_2969459074.webp)
15 Near-end crosstalk (NEXT)
74
ARGUS Copper Box
Example measurements:
If there is no crosstalk between line pair 1
and line pair 2 (adjacent line), a maximum
value is reached (in this example 65 dB).
However, a value >37 dB (as in this
example 37.7 dB) considered sufficient.
The crosstalk to the adjacent line is
tolerable.
If a value <37 dB is measured, or even
5.8 dB as in this example, there may be a
short between the two wire pairs. The
tone is 100 % cross-coupled and severely
interferes with the line.