![Argus Copper Box v4 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/argus/copper-box-v4/copper-box-v4_manual_2969459015.webp)
3 General technical data
ARGUS Copper Box
15
Isolation resistance measurement with 105 V, max. 2 mA (Iso.):
Measuring range:
Resolution:
Accuracy:
0.1
Ω
- 99.9
Ω
0.1 k
Ω
±(2 % + 1 digit)
100.0 k
Ω
- 999.0 k
Ω
1 k
Ω
±(2 % + 1 digit)
1.00 M
Ω
- 9.99 M
Ω
10 k
Ω
±(2 % + 1 digit)
10.0 M
Ω
- 99.9 M
Ω
100 k
Ω
±(5 % + 1 digit)
100.0 M
Ω
- 999.9 M
Ω
100 k
Ω
±(5 % + 1 digit)
Isolation resistance measurement with 8 V, max. 9 mA (Iso.):
Measuring range:
Resolution:
Accuracy:
0.1
Ω
- 99.9 k
Ω
0.1 k
Ω
±(2 % + 1 digit)
100.0
Ω
- 999.0 k
Ω
1 k
Ω
±(2 % + 1 digit)
1.00 M
Ω
- 9.99 M
Ω
10 k
Ω
±(2 % + 1 digit)
10.0 M
Ω
- 40.0 M
Ω
100 k
Ω
±(5 % + 1 digit)
Resistance difference (R
Sym
):
Measuring range:
Resolution:
Accuracy:
10
Ω
- 5 k
Ω
0.1
Ω
± 0.2 % of R
Loop
± 0.2
Ω
Loop resistance measurement with 13 V, max. 15 mA (Iso.):
Measuring range:
Resolution:
Accuracy:
0.1
Ω
- 999.9 k
Ω
0.1
Ω
±(1 % + 3 digits)
1.000
Ω
- 9.999 k
Ω
1
Ω
±(1 % + 1 digit)
10.00
Ω
- 99.99 k
Ω
10
Ω
±(1 % + 1 digit)
100.0
Ω
- 999.9 k
Ω
100
Ω
±(1 % + 1 digit)
1.000 M
Ω
- 9.999 M
Ω
1 k
Ω
±(2 % + 1 digit)
10.0 M
Ω
- 40.0 M
Ω
10 k
Ω
±(5 % + 1 digit)
DC current measurement (I=):
Measuring range:
Resolution:
Accuracy:
0.1 mA - 499.9 mA
0.1 mA
±(2.5 % + 3 digits)