15 Near-end crosstalk (NEXT)
ARGUS Copper Box
71
15 Near-end crosstalk (NEXT)
ARGUS generates a 1 MHz tone on line pair 1 and measures the crosstalk on the adjacent
line pair 2, which can cause severe performance issues for DSL. A customer's line can
pass through multiple segments. In this case, the measurement must be performed
segment by segment, and different line pairs may need to be used as the measuring lines.
A voltage check is performed before the measurement in which the voltage
limits given in the table (see page 11) may not be exceeded.
The length of the measuring leads can significantly affect the measurement,
so you should always perform your measurements using the original
accessories.
The measuring ranges, resolutions and accuracies of NEXT measurement are set out in
the chapter Technical data, see page 14.
Connection example (towards to the customer):
* Measurement is also
possible from the street
cabinet towards the
customer (segment by
segment).
Connection example (towards to the MDF):
* Measurement is also
possible from the street
cabinet towards the
MDF (segment by
segment).