14 Longitudinal conversion loss (LCL)
68
ARGUS Copper Box
14 Longitudinal conversion loss (LCL)
LCL measurement (asymmetry attenuation) looks at the balance between the Tip-wire with
respect to Ground (GND) compared to the Ring-wire with respect to Ground. In this
measurement, a tone is fed symmetrically to the wires with respect to Ground at 1 MHz. If a
difference can be measured between the two wires, an asymmetry is present.
A voltage check is performed before the measurement in which the voltage
limits given in the table (see page 11) may not be exceeded.
The length of the measuring leads can significantly affect the measurement,
so you should always perform your measurements using the original
accessories.
The measuring ranges, resolutions and accuracies of the LCL measurement are set out
in the chapter Technical data, see page 14.
LCL measurement settings
ARGUS in the status display.
The LCL measurement is not yet started.
Hotkeys/settings of LCL measurement
see page 20 and in the sheet under.
<Menu>
Opens the Copper Box
<Start>
Starts the LCL measurement.