9 Capacitance measurement (C)
46
ARGUS Copper Box
9 Capacitance measurement (C)
Capacitance measurement shows the typical input capacitance of connected devices or the
capacitance of the open line.
The line must be open. This can be ensured using the instrument kit
function "open circuit". Before the measurement, a voltage check is
performed in which the voltage limits given in the table (see page 11) may
not be exceeded.
The measuring ranges, resolutions and accuracies of the capacitance measurement may
be found in the chapter Technical data, see page 14.
Capacitance measurement settings
ARGUS in the status display.
Capacitance measurement is not yet
started.
Hotkeys/settings of capacitance mea-
surement see page 20 and in the sheet
under.
Once you have measured C-symmetry, you no longer need to measure
capacitance.
When you select the susceptibility
"Insecure (fast)", the red warning
"ATTENTION: susceptible"
appears on the display.
<Menu>
Opens the Copper Box
<Start>
Starts capacitance
measurement.