5 Using the ARGUS Copper Box v4
23
ARGUS Copper Box
In this example, sockets Tip, Ring and
GND are selected.
Each measurement between two sockets (e.g. on Tip/Ring) is always performed
in real time.
5.4 Alarm tones
ARGUS generates various alarm tones in conjunction with the Copper Box, for instance as
soon as a fault occurs or a test has been concluded. The alarm tones must be activated in
the ARGUS settings, see Main Manual.
Short - short
Fault:
- Immediately when an external voltage is detected.
- In the absence of a loop or ground (R
Sym
).
- In the absence of a ground/line or presence of a loop (C
Sym
).
Short - long
Test complete:
- After every test that ended automatically.
- After every auto test - (not after every individual test here).
Short - short -
long
In the event of a fault at the end of a test.
Long
Prompts for user input.
<Menu>
Opens the Copper Box
menu, see page 20.
<Start>
Starts voltage measurement
via sockets Tip. Ring and
GND.