List of preconfigured default wire types:
No. Name
Wire
diameter
(mm)
Line
resistance
(Ohm/km)
Mutual
capaci-
tance
(nf/km)
VoP
(%)
Note
1
PE 0.5 AWG24
0.5
80
39
66.0
Outdoor cable, Poly-
ethylene, air filled
2
PP 0.5 AWG24
0.5
80
39
66.0
Outdoor cable, Poly-
propylone, air filled
3
Pulp 0.4 AWG26 0.4
150
36
60.0
Outdoor cable, conductor
with pulp jacket, air filled
4
Pulp 0.5 AWG24 0.5
80
39
67.0
Outdoor cable, conductor
with pulp jacket, air filled
5
Pulp 0.6 AWG22 0.6
65
38
68.0
Outdoor cable, conductor
with pulp jacket, air filled
6
PIC 0.4 AWG26 0.4
150
36
64.0
Outdoor cable, conductor
with plastic jacket, air filled
7
PIC 0.5 AWG24 0.5
80
39
66.0
Outdoor cable, conductor
with plastic jacket, air filled
8
PIC 0.6 AWG22 0.6
65
38
67.0
Outdoor cable, conductor
with plastic jacket, air filled
9
PIC 0.9 AWG19 0.9
29
34
72.0
Outdoor cable, conductor
with plastic jacket, air filled
10 Jelly 0.9 AWG19 0.9
29
34
68.0
Outdoor cable, petroleum/
jelly filled cable
11
Filled 0.4
AWG26
0.4
150
36
58.0
Outdoor cable, filled
12 Filled 0.5
AWG24
0.5
80
39
60.0
Outdoor cable, filled
13 Filled 0.6
AWG22
0.6
65
38
62.0
Outdoor cable, filled
14 PTFE/Teflon 0.5
AWG24
0.5
80
39
67.0
Outdoor cable, conductor
with teflon jacket
15 Wire type 15
-
80
49
66.7
default, editable
16 Wire type 16
-
80
49
66.7
default, editable
17 Wire type 17
-
80
49
66.7
default, editable
18 Wire type 18
-
80
49
66.7
default, editable
19 Wire type 19
-
80
49
66.7
default, editable
20 Wire type 20
-
80
49
66.7
default, editable