51
CNC System Instruction
7.3. Flame Cutting Parameters
In the SETUP submenu, press [F3] key to enter flame parameters setting window, as shown in Fig. 7.4.
Ignition delay——
It is the time delay when turn on the high voltage ignition switch if M20 is executed in flame cutting operation.
Preheating delay——
It is the preheating time for piercing operation in second. If the preheating time is insufficient, it will be prolonged to 150
seconds automatically by pressing [PAUSE] key. If preheating is done in the midway, press [START] key to abort the time delay. The new preheating
time will be automatically saved in the parameter of preheating delay.
Lifting delay of cutting torch——
The time delay when M70 command is executed in second. Refer to 6.4 for M auxiliary commands.
Lowering delay of cutting torch——
The time delay when M71 command is executed, in second. Refer to 6.4 for M auxiliary com-
mands.
Lifting delay of piercing torch——
The time delay when M72 command is executed, in second. Refer to 6.4 for M auxiliary com-
mands.
Lowering delay of piercing torch——
The time delay when M73 command is executed, in second. Refer to 6.4 for M auxiliary com-
mands.
Piercing delay——
Lowering delay of cutting torch when M07 is executed in flame piercing operation after cutting oxygen valve
is opened.
7.4. Plasma Parameters Setting
In the SETUP submenu, press [F4] key to enter plasma parameters setting window, as shown in Fig. 7.5.
Fig. 7.4 Flame parameters setting
Fig.7.5 Plasma Parameters Setting