68
Front Panel Menu System
8.8.4
Programmable Pulse: Pulse-Per-Day Mode
Use the “PULSE PER DAY?” mode to generate a pulse every day, at the specified hour, minute,
second and fractional seconds. Configure as illustrated in Figure 8.12. Refer to Section 8.8 above
for additional detail on the Programmable Pulse mode, and entering numerical values.
Setting values are Hours, Minutes, Seconds, Fractional Seconds, Programmable Pulse Width and
Time Zone (Local or UTC).
For RS-232 commands, see Section 11.2.10
SET PROG. PULSE?
ENTER
SETUP
MODE
PULSE PER DAY
DOWN
UP
ENTER
HOUR
00
DOWN
UP
ENTER
23
|
00*
TIME
UTC
DOWN
UP
ENTER
LCL
UTC*
MINUTE
00
DOWN
UP
ENTER
59
|
00*
SECOND
00
DOWN
UP
ENTER
59
|
00*
FRACTIONAL SECOND
00
DOWN
UP
ENTER
99
|
00*
PULSE WIDTH
0.01
DOWN
UP
ENTER
600
0.01*
|
DCF77 modified
DCF77
SLOW CODE
SINGLE TRIGGER
IRIG-B
PULSE PER DAY
PULSE PER HOUR
SECONDS PER PULSE*
PROG. PULSE OFF
POLARITY
(+)
DOWN
UP
ENTER
(–)
(+)*
* = Default Setting
Figure 8.12: Pulse-Per-Day Setup
Содержание 1200B
Страница 4: ...iv ...
Страница 135: ...A 3 Physical Dimensions 117 Figure A 2 Suggested Mounting of the GNSS Surge Arrester ...
Страница 143: ...B 7 Four Fiber Optic Outputs 125 Figure B 4 Jumper Locations ...
Страница 145: ...B 8 8 Channel High Drive IRIG B Amplifier 127 Figure B 5 8 High Drive Outputs Jumper Locations ...
Страница 161: ...B 10 Four Additional Outputs and Dry Contacts 25 50 Vdc 143 Figure B 7 Option Connector Signal Locations ...
Страница 212: ...Appendix E Statement of Compliance The following page is a statement of compliance that includes Model 1201B and 1201C ...