12
6
WIRING CONNECTIONS
• Use only the cables provided with the ARAG computers.
• Take care not to break, pull, tear or cut the cables.
• Use of unsuitable cables not provided by ARAG automatically voids the warranty.
• ARAG is not liable for damages to the equipment, persons or animals caused by failure to observe the above instructions.
6.1
General precautions for a correct harness position
• Securing the cables:
- secure the harness so that it does not interfere with moving parts;
- route the harnesses so that they cannot be damaged or broken by machine movements or twisting.
• Routing the cables to protect against water infiltrations:
- the cable branches must ALWAYS be face down (Fig. 10).
Fig. 10
Fig. 11
• Fitting the cables to the connection points:
- do not force the connectors by pushing too hard or bending them: the contacts may be damaged and computer operation may be compromised.
Use ONLY the cables and accessories indicated in the catalog, having technical features suitable for the use to be made of them.
6.2
Switch panel connection
Fasten connectors (see connection points under par. 5.2), ensure they are correctly in place and turn the ring nut clockwise until blocking them.
6.3
Control unit (ECU) connection
Connect wiring harnesses as indicated under par. 5.2; each of them must be connected to the corresponding socket on control unit.
If they prove hard to insert, do not force them, but check the shown position.
Fig. 12
• Open connector slide (
1
,
• Position connector (
2
) and insert it inside socket (
3
), then press:
during this operation, take special care not to bend electric contacts
.
• Close slide (
4
) until it locks in place.