74
USE
12.2.1 "Buffer Zone" function enabled
Some spraying jobs provide for zones called "Buffer zone", where spraying must be reduced or shut off.
Further to the nozzles usually used, it is necessary to install special nozzles (e.g.: ASJ AOC), able to reduce the spray or drift, as terminal nozzles
on boom.
Fig. 239
Buffer zone
Buffer zone
If this function is enabled under implement basic settings (chap. 9) it is possible to alternatively select standard or special nozzles.
• Activation of the left-hand special nozzle (when looking at the boom from behind)
Press switch once to the left to activate the left-hand nozzle for "Buffer zone" and close the standard nozzle. The LH LED blinks.
• Activation of the right-hand special nozzle (when looking at the boom from behind)
Press switch once to the right to activate the right-hand nozzle for "Buffer zone" and close the standard nozzle. The RH LED blinks.
• Deactivation of the left-hand special nozzle (when looking at the boom from behind)
Press switch once to the right to deactivate the left-hand nozzle for "Buffer zone" and open the standard nozzle. The LH LED stops blinking and
will stay on steadily.
• Deactivation of the right-hand special nozzle (when looking at the boom from behind)
Press switch once to the left to deactivate the right-hand nozzle for "Buffer zone" and open the standard nozzle. The RH LED stops blinking and
will stay on steadily.
12.3
Operating switches for hydraulic valves
Release
of the boom
Block
of the boom
Leveling
of the boom
clockwise
Leveling
of the boom
counter-clockwise
Increase
height
of the boom
Decrease height
of the boom
Boom section
movement:
opening
Boom section
movement: closing