120
18
TECHNICAL DATA
DESCRIPTION
Delta 80
Display
LCD 8.4", 65000 colors, 500 cd/m
2
Rated supply voltage
12 Vdc (9 ÷ 16 Vdc)
Consumption (valves excluded)
monitor: 1.5 A
Operating temperature
0 °C ÷ 45 °C
+32 °F ÷ +113 °F
Storage temperature
-20 °C ÷ 60 °C
-4 °F ÷ +140 °F
Digital inputs
for open collector sensors: max 2000 imp*/s
Analog input
4 ÷ 20 mA
Weight (without cables)
monitor: 2240 g
2 USB 2.0 ports
HOST
Protection against polarity inversion
•
Protection against short-circuit
•
18.1
Data and units of measurement shown
Implement
Menu
Data
Min. Max.
UoM
DEFAULT
Other values that can be set / Notes
Spray spots
configurations
Number of nozzles for each spraying point
--
--
n°
1
2, 4
Selection during guided setup
Spraying point 1
Nozzle A
--
--
--
Nozzle:
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
Nozzle B
--
--
--
Disabled
Nozzle C
--
--
--
Disabled
Nozzle D
--
--
--
Disabled
Spraying point 2
Nozzle A
--
--
--
Nozzle B
--
--
--
Disabled
Nozzle C
--
--
--
Disabled
Nozzle D
--
--
--
Disabled
Spraying point 3
Nozzle A
--
--
--
Nozzle B
--
--
--
Disabled
Nozzle C
--
--
--
Disabled
Nozzle D
--
--
--
Disabled
Spraying point 4 ÷ 20
--
--
--
Disabled
Boom settings
Spray spots spacing
1
1000
cm
50 cm
0.39 393.70 inches
19.68 inches
Sections number
1
13
n°
--
Variable setting defined by the connected switch panel
Section 1 ÷ 13
1
50
n°
4
Number of spraying points for each section
Activation status of the
sections
Section 1 ÷ 13
--
--
--
Enabled
Disabled
Flowmeter
Type
--
--
--
Orion
462xxA4xxxx
Orion 4621xA0xxxx, Orion 4621xA1xxxx, Orion 4621xA2xxxx,
Orion 4621xA3xxxx, Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x2xxx, Wolf 462x3xxx, Wolf 462x4xxx, Wolf 462x5xxx,
Wolf 462x7xxx,
Other
Constant
1
32000
pls*/l
--
Fixed settings for each flowmeter except
Other
4
32000 pls*/gal
--
Minimum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Maximum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Filling flowmeter
Type
--
--
--
Orion
462xxA4xxxx
Orion 4622xA5xxxx, Orion 4622xA6xxxx,
Wolf 462x4xxx, Wolf 462x5xxx, Wolf 462x7xxx,
Other
Constant
1
32000
pls*/l
--
Fixed settings for each flowmeter except
Other
4
32000 pls*/gal
--
Minimum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Maximum flowrate
0.1
999.9
l/min
--
0.1
264.1
GPM
--
Pressure sensor
Status
--
--
--
Disabled
Enabled
Type
--
--
--
466113.200
466113.500,
Other
Maximum pressure
0.1
150.0
bar
--
Fixed settings for each sensor except
Other
1
2175
PSI
--
Valves
Main valve
Type
--
--
--
3 ways
2 ways,
None
Selection during guided setup
Automatic closing of
sections valves
--
--
--
Enabled
Disabled
Selection during guided setup
Automatic closing of
main valve
--
--
--
Disabled
Enabled
Switching time
0.1
1.0
s
1.0 s
Pressure regulating
valve
Regulation direction
--
--
--
Standard
Reverse
Section valves
Type
--
--
--
2 ways
Automatic selection during guided setup
Shut-off time
0.1
1.0
s
0.3 s
Switch-on time
0.1
1.0
s
0.3 s
TECHNICAL DATA
*
pls = pulse
CONTINUES > > >