16
6.6
Sensor connection
Fix the connectors to the relevant functions according to the initials indicated in your assembly general diagram (par. 5.1).
Harness cables are marked with a symbol denoting their functions: please see the table for correct harness connection.
Use ARAG sensors: use of unsuitable sensors not provided by ARAG automatically voids the warranty.
ARAG is not liable for damage to the equipment, persons or animals caused by failure to observe the above instructions.
ITEM
CONNECTION
F
Flowmeter
L
Level sensor
M
Pressure sensor
S
Speed sensor
T
Filling flowmeter
X
RPM sensor
- The products are supplied with the sensor installation instructions.
The following speed sensors can also be used as RPM sensors:
• inductive speed sensor (
code 467100.086);
• magnetic speed sensor (
code 467100.100).
- Connection of:
• flowmeter;
• pressure sensor;
• level sensor
• filling flowmeter;
• RPM sensor.
All ARAG sensors use the same type of connector. Connect the sensor connector to the relevant harness; make sure it is correctly fitted and push it
until locking it.
Fig. 22
Fig. 23
6.7
Camera connection
Delta 80 can be connected to one or two cameras
code 46700100
(purchased separately) using the suitable cables listed in the ARAG general catalog.
Connect the connector to the monitor (see connection points at par. 5.2) and the other cable end to the camera: ensure it is correctly in place and
turn the ring nut clockwise until blocking it.
6.8
Power supply connection
WARNING:
To avoid short circuits, do not connect the power cables to battery before the installation is completed.
Before powering up the computer, make sure the tractor battery voltage is as specified (12 VDC).
Delta 80 is supplied directly by the farming machine battery (12 VDC): ALWAYS switch on the system through the computer, and then remember to
switch it off using the specific key on the control panel.
If Delta 80 remains on for a long time with machine off, the tractor battery could run flat: in case of prolonged breaks of the
machine with engine off, make sure the computer is off, too.
The power source must be connected as indicated in Fig. 24:
Fig. 24
Connect the power cable directly to the battery using the
suitable eyelets.
WARNING! DO NOT connect to key-operated switch (15/54).