10
SETUP
"BASIC SETTINGS"
9
BASIC SETTINGS
GUIDED SETUP PROCEDURE UPON FIRST SWITCHING ON
1 LANGUAGE SETTING
- In the "Home" screen (Fig. 19) press
F8
to enter the
Settings
menu (Fig. 20).
- Select
General options > Language
and set the language of Navigator.
- Press
ESC
and return to the
Settings
menu. Now select
Implement
to start guided setup procedure as shown in Fig. 21.
1
Fig. 19
Fig. 20
For a correct use of the keys
during setting, refer to par. 7.4.
2 IMPLEMENT
- Upon first switching on, Navigator starts the guided setup procedure for the
Implement
: go through each step selecting the desired options (example in Fig. 22).
OK
: next step
ESC
: previous step.
- When the message in Fig. 23 appears, the implement setup is complete. Press
OK
.
- Press
ESC
and return to the
Settings
menu. Now select
Tractor
to start guided setup procedure as shown in Fig. 24.
Fig. 21
OK
Next step
ESC
Previous step
Fig. 22
Fig. 23
BASIC IMPLEMENT SETTINGS
• IMPLEMENT TYPE
Sprayer (Seletron)
: system with Seletron valves.
Sprayer (Electrovalves)
: system with electric-activated valves - with gearmotor.
GPS guidance monitor
: Navigator is only used as a driving aid and does not control spraying (it is not connected to the RCU).
• IMPLEMENT CONNECTION TYPE
Rear 3-point hitch
Towing hitch
Front 3-point hitch
• SWITCH PANEL TYPE
Sequential section switches
: switch panel with sequential control.
5 section switches (Direct)
: 5-way switch panel.
7 section switches (Direct)
: 7-way switch panel.
External command
: no switch panel: spraying enabled through external main control.
Keyboard
: no switch panel: spraying enabled through monitor keyboard.
CONTINUES > > >
Par.
Exit the function
or data change
Confirm access
or data change
Scroll
(LEFT /
RIGHT)
Delete
selected
character
Data
increase /
decrease
Scroll
(UP /
DOWN)
Enter
selected
character